background image

 

 

 

 
 

1.2 

Intended Applications 

 

Only  use  the  mobile  Microfiltration System MOT-7  as well  as  any  accompanying accessories  /

 

components per 

manufacturer’s instructions. Intended usage is discussed in these instructions. 

 

In  order  to  ensure  the  mobile  Microfiltration  System  MOT-7  can  perform the  described  level  of

 

treatment, the parameters set out must be followed. In addition, the physical and chemical parameters

 

for  drinking  water  as  required  by state-specific requirements for  drinking water  fit for  human

 

consumption must also be adhered to. 

 

The  mobile  Microfiltration  System  MOT-7  has  been  designed  and  built  based  on  state-of-the-art

 

technology, in order to provide safe operation when safety regulations and operating requirements are

 

followed. 

 
 

 

Working on the mobile Microfiltration System MOT-7 as well as operation and use of the

 

system is permitted only when the unit is in good condition technically and when attention

 

is  paid  to  safety  standards  and  to  potential  hazards  as  described  in  these  operation

 

instructions, the handbook, as well as in this supplement. 
Only when these are followed without exception can operators and others avoid the loss

 

of  life  and  serious  injuries or  avoid  interference  with  the 

system’s  operation  or  other

 

material assets. 

 

Appropriately trained specialist must immediately repair malfunctions, damage, or resolve

 

abnormal operations that could compromise safety! 

 
 

 

Safety gloves with sufficient protection must always be worn when performing any
maintenance on the mobile Microfiltration System MOT-7. 

Always  properly  dispose  of  waste  products,  in  particular  fluids  in  the  pump  unit,  at
designated locations or with specialists. 

In  order  to  avoid  accidents  and  possible  work  disability resulting  from  accidents  due  to
improper  operation  of  the  Katadyn  mobile  Microfiltration  System  MOT-7,  please
observe  and  follow  pertinent  safety  procedures.  Improper  handling  of  the  Katadyn
mobile  Microfiltration  System  MOT-7  can  put  health  at  risk.  Operating/handling  duties
may only be performed by trained personnel. 

Only open the filter chamber when it is unpressurized and emptied. 

Before cleaning, maintenance, repair or replacement of parts, the hydraulic unit must first
be depressurized, and the pump unit turned off. These duties may only be performed by
trained personnel. 

Summary of Contents for MOT-7

Page 1: ...1 MobileMicrofiltrationSystem MOT 7 Water treatment with Katadyn ceramic filters...

Page 2: ...entration 7 3 6 Installation requirements of components 8 3 7 Flow rates of the MOT 7 8 4 1 Setup Procedure 9 5 1 Setup procedure 10 6 1 Brief description of the handle position of operational compone...

Page 3: ...eral Safety Guidelines The mobile Microfiltration System MOT 7 from Katadyn has been factory tested The dangers of improper use or failing to follow the operating procedures outlined in this manual ma...

Page 4: ...in this supplement Only when these are followed without exception can operators and others avoid the loss of life and serious injuries or avoid interference with the system s operation or other materi...

Page 5: ...safety operations and maintenance instructions and improper repairs Improper use of the MOT 7 use not in compliance with instructions Use of repair parts not permitted by the MOT 7 manufacturer Opera...

Page 6: ...filters are made from various natural raw materials of the highest quality standard As such we can attain a nominal pore size of 0 2 m with insignificant variations 3 2 Primary features of mobile micr...

Page 7: ...ments become dirtier the flow rate also decreases accordingly Intervals between cleanings can be influenced positively with the appropriate placement of the suction hose Placing the hose directly unde...

Page 8: ...resh water outlet Drain water outlet Cleaning hose connection hose is enclosed Sample valve outlet 3 7 Flow rates of the MOT 7 The above chart shows the typical performance of the unit when operated i...

Page 9: ...6 kW Rated speed 3600 U min Tank Capacity 3 1 L Consumption l h 1 6 Measurements LxWxH 435 x 375 x 400 mm Weight 23 5 kg Please refer to the accompanying Honda Manual regarding the correct handling o...

Page 10: ...ice 5 1 Setup Procedure Take care that the filter unit is placed in a stable position and that the location surface is dry Remove the No 5 filter elements from the package and screw them hand tight in...

Page 11: ...11 Hook up the cleaning hose to the corresponding threads The MOT 7 is now ready for use...

Page 12: ...t Valve B Sample Valve E Open Close 6 2 Filling Venting Check that all valves are closed Start the motor and vent the pump Turn the main valve A counter clockwise to open Open vent valve B just slight...

Page 13: ...g 6 5 Water Sampling Sampling must be performed by an experienced person according to DIN EN 25667 2 procedures The mobile Microfiltration System MOT 7 must be set in the operational mode see chapter...

Page 14: ...lve D as soon as the filter elements are standing in water by 1 6 only Put the cleaning brush over the filter element and move it up and down 6 8 times and at the same time flush with water from the p...

Page 15: ...the Pump Open cleaning valve C Clean the filter elements and inside of the housing with the cleaning hose Close cleaning valve C Stop the Pump Open the drain valve D and empty the filter housing Repla...

Page 16: ...se the sampling valve Pump unit delivers too little water Motor is not running at the max speed Suction filter not completely covered in water or dirty Optimize the suction filter Clean the filter Suc...

Page 17: ...t Number Description Picture 7010719 V Band Clamp M MOT7 MF 7 20621 SET Cleaning Hose M MOT7 complete 20616 Cleaning Brush for Katadyn Filter elements 20335 Measurement gauge for Katadyn Filter elemen...

Page 18: ...tadyn Filter element No 5 128031 O Ring Seal 268 x 16mm 7010633 Suction Hose M MOT7 incl coupling to Pump 20615 1 Pair of Brush Segments Nylon 20619 1 Pair of Brush Segments Bronze Option for difficul...

Reviews: