13
Operational Procedures
6.1 Brief description of the handle position of operational components
Main Valve A
Drain Valve D
Open
Close
Vent Valve B
Cleaning Valve C
Open
Close
6.2 Filling / Venting
Check that all valves are closed
Start the motor and vent the pump
Turn the main valve A counter clockwise to open
Open vent valve B just slightly
When water appears, close vent valve B (Caution: Water may
begin flowing forcefully!)
Now the mobile microfiltration system MOT-31/54 is ready for use