Kasco Robust-Aire RA1-PM Owner'S Manual Download Page 13

 

                                                                                                                                                                                        

13                                                                                  

 

OWNERS MANUAL 

 

Warranty Claim Procedure: 

The best method for establishing warranty period is by the original receipt. Register your system online at: 

www.kascomarine.com

 

Once the warranty coverage has been established, the unit may be sent to a Kasco Authorized Repair Center 

for evaluation and repair. Please contact Kasco Marine prior to shipping to receive any updated information 

and/or repair form. 

 

Shipping Address: 

Kasco Marine, Inc.  

800 Deere Rd.  

Prescott, WI 54021  

Attn: Repairs 

 

Call or email Kasco Marine to locate your nearest Authorized Repair Center.  

 

715-262-4488 

[email protected]

 

Please include the Repair Form with the shipment. If no Repair Form is available, include: 

Name, Physical address (for return delivery of the repaired unit), Daytime phone number, and E-mail address 

for correspondence regarding the warranty claim. 

 

Expedited shipping

 for the return of the unit is at the customer’s expense. Kasco will return units repaired 

under warranty at our expense via ground freight within the continental United States. 

 

Other Repairs

Failed equipment can be repaired, often at substantially lower costs than replacement. Please ship according to 

above instructions. Contact Kasco for updated information and/or repair form. 

 

Kasco Marine does estimates on repairs at the customer’s request. This request should be included in the 

documentation that accompanies the returned unit and must include a daytime phone number and/or e-mail 

address. We will contact the customer with a total after the unit has been evaluated, but before the work is 

performed.  

 

All estimates that are rejected for repair will be recycled unless otherwise directed by the customer. If the unit is 

to be returned, it will be assembled to the condition in which it was received and shipped at the customer’s 

expense. 

 

 

Billing

All non-warranty repairs will be returned to the customer and billed C.O.D. unless otherwise directed. Kasco 

Marine also accepts Visa and MasterCard upon completion of the repair. 

 

Summary of Contents for Robust-Aire RA1-PM

Page 1: ...Robust Aire Owner s Manual 800 Deere Rd Prescott WI 54021 715 262 4488 sales kascomarine com kascomarine com PN 772155 Rev 6 2020...

Page 2: ...when dealing with any electrical equipment Caution should be used around water Running the system in below freezing conditions may create open areas of water at the diffuser locations and thin ice in...

Page 3: ...ct any number of 100 lengths together and have someone assist in feeding it from shore The excess tubing can then be cut off at shore before connecting to the compressor 4 Drop loose end of the tubing...

Page 4: ...x 3 4 bolt 4 10 split washer 4 10 Nut 1 3 length of 3 8 hose 3 Hose Clamp 1 Intake Hose 1 Intake Block 1 Filter Minder 1 Air Filter Parts included in RA H 2 NC Systems 2 Robust Aire Diffuser Assembly...

Page 5: ...reSink Tubing w fitting kit 2 Double Head Compressor 4 NPT x 3 8 barb brass elbow 8 Compressor Vibration Isolation Feet 8 Flat Washer 8 Lock Nut 2 Cooling fan assembly either 115V with plug or 230V wi...

Page 6: ...easy mounting to a wall floor or bench After the proper location has been determined use the following diagrams to complete the installation 120V compressors are supplied with a NEMA 5 15 plug 240V c...

Page 7: ...nts will not be blocked as air flow is required to keep the compressor from over heating The assembly can be placed directly on the ground or attached to a concrete pad The bottom flanges have holes w...

Page 8: ...ost mount cabinet Drill 2 3 16 holes vertically spaced 2 3 8 apart Install 1 lag screw into the wall or post leaving the hex head out about using a standard 7 16 socket wrench Hang the cabinet from th...

Page 9: ...to 8 deep For two or three station valve manifolds excavate an area large enough to bury the included valve box An area at least 18 wide by 25 long x 13 deep will be needed Dig the area deeper and add...

Page 10: ...at can be harmful to fish Also the colder bottom water often has little or no dissolved oxygen present A simple test for thermal stratification is to place a thermometer into the body of water and gra...

Page 11: ...a minimum of 3 feet into the water at low water level Using closed cell polyurethane foam to insulate will prevent ice buildup in the lines Ice buildup can block the flow of air to your diffuser and c...

Page 12: ...d replacement Please contact Kasco or your distributor if problems persist Warranty Diffuser Assembly 5 years Teich Aire compressor 2 years Exterior Cabinet 5 years SureSink Tubing 10 years Kasco Mari...

Page 13: ...he customer s expense Kasco will return units repaired under warranty at our expense via ground freight within the continental United States Other Repairs Failed equipment can be repaired often at sub...