C-25 CONTROL PANEL MANUAL
2
1
Set ON / AUTO switch.
Current time
indicator
Evening hours Daytime hours
2
Push trippers toward outer
ring to set activation times.
Turn this dial to set
the current time.
3
Set trippers in groups of four
(minimum) for one hour of activation.
The C-25 will turn the Kasco aerator/fountain ON or OFF with the timer. Kasco lights will turn ON or OFF with
the photo eye only when the timer is ON. If the timer is OFF, the light outlet will not energize.
1. Push each tripper to the outer ring for every 15 minutes of activation time.
2. Set the current time by turning the innermost dial (clear) clockwise to advance the hour and minute
hands until the clock face displays the correct time AND the “TIME NOW” arrow is indicating the current
time on the outermost dial. (Note the PM hours are indicated by a black line at the outer edge.)
• Setting the time by spinning the inner dial will help to avoid turning either dial too quickly.
3.
Set the AUTO/ON switch to AUTO for automatic timer control.
4.
Plug the aerator/fountain cord into the right side outlet (labeled UNIT).
5. Plug light kit cord into left side outlet (labeled LIGHT).
For most efficient and effective operation, set the timer in segments of one-hour activation time or
greater. (Set four trippers together for 1 hour minimum runtime). If you set the timer switch to ON,
the aerator/fountain will operate continuously and lights will turn on/off by the photo eye.
TIMER INSTRUCTIONS
The GFCI should be checked every month to ensure it is operating properly. Follow the steps below. Kasco
recommends maintaining a record of your monthly safety check.
1.
Push the TEST button on the GFCI. The RESET button will pop out and the GFCI should turn off (no power
to the receptacles).
• You can verify by plugging a test lamp into the outlets. Be sure the timer is set to ON. You may need
to cover the photo eye to send power to the light receptacle.
2. If the GFCI tests okay, restore power by pushing the RESET button back in. The test lamp will illuminate if
power is restored. The RESET button must be pushed firmly into place (with your finger) until it locks and
remains latched after pressure has been removed.
WARNING:
If the RESET button does not pop out, if the test lamp remains lit when the TEST button is
pressed, or if the GFCI fails to reset properly, DO NOT USE the C-25. Contact a qualified service technician
for assistance.
GFCI TEST PROCEDURE
Back to Contents