11

ratings.  Electrical installation must follow local and 
national electrical codes and should be installed by a 
professional.

Maintenance Recommendations

 

Under No Circumstances should anyone enter 

the water while a unit is operating. Turn Off and Dis-
connect electrical power prior to any Maintenance or 
Servicing

RCD (Residual Current Device) or GFCI are a safety 
feature that can also alert you to electrical leaks in the 
equipment.  It is extremely important to test the RCD 
upon installation, each reinstallation, and monthly 
thereafter to ensure proper operation.  If you have re-
peat, consistent trips on your ground fault (RCD), the 
equipment should be disconnected and removed from 
the water.  The power cord should be inspected for 
damage and you should call a Kasco Marine distribu-
tor or representative for further instructions.

If the supply cord becomes damaged, it must be 
replaced by an authorized service center, or similarly 
qualifi ed persons in order to avoid a hazard.

OBSERVATION:  Operating equipment should be 
observed on a regular basis (daily, if possible) for any 
reduction or variation in performance.  If a change in 
performance is observed, the equipment should be dis-
connected from power and inspected for any material 
that may have clogged the system or wrapped around 
the shaft of the motor, especially plastic bags and fi sh-
ing line.  Even though Kasco Fountains are among the 
most clog-resistant on the market, it is impossible to 
protect against all items that can clog equipment and 
still maintain a fl ow of water.  These materials can 
be very damaging to the equipment under continued 
operation and must be removed as soon as possible.  
ALWAYS DISCONNECT POWER TO THE UNIT 
BEFORE ATTEMPTING TO REMOVE CLOGS.

WINTER STORAGE:  In regions where there is sig-
nifi cant freezing in the wintertime, Fountains should 
be removed from the water to protect them from the 
expansion pressure of the ice.  Storage over winter is 

ter).  Anchor the ropes or secure them to the shoreline 
so the ropes are free of slack, but not tight.  To prevent 
twisting of the unit due to torque, you should place 
the anchor at least 3m from the fl oat for each meter of 
depth (Ex. A 3m deep pond would require an anchor 
9m horizontally from the fl oat.)  For ease of removal, 
you may choose to keep at least one anchor within 
reach from shore, just below the water’s surface.

Correct Anchoring

Incorrect Anchoring

STEP TWO (ALTERNATE INSTALLATION)
In ponds where the water level fl uctuates signifi cantly, 
you may need to suspend a small weight (30cm of 
2.54cm galvanize pipe works well) at the mid-point of 
the rope to take up any slack as the water level drops.  
The weight should be light enough so the Unit can rise 
as the water level rises.  This can also help hide ropes 
by sinking them further below the surface.

Normal Water level

Power Cord

Anchor Rope

Secondary Weight

Low Water Level

Kasco Power 
Control Box

High Water Level

STEP THREE
At this time the Fountain is ready for operation.  The 
unit can now be connected to the electrical circuit 
(fi xed wiring) with a plug or direct wire connection.  
The circuit must be provided with a disconnect switch, 
short circuit, and ground fault protection (RCD).  
Refer to unit specs for voltage and amperage ratings.  
Also, the motor name plate lists the unit’s electrical 

Summary of Contents for 8400EJ

Page 1: ...ukset 2 Tekniset tiedot 3 K ytt virtavaatimukset 3 Pikaliitinasetus 3 Johtojen ja tiivisteiden koko 5 Mukana tulee 5 Kokoamisohjeet 6 EVX mallin koot 8 Mallin JF suutinvaihtoehdot 8 3 vaihek ynnistys...

Page 2: ...vioittua Viittaa 3 vaihek ynnistykseen Kiinteiss johdoissa on oltava paikallisten ja maan asennuss d sten mukainen keino kytke ne irti jotta laite ei voi k ynnisty vahingossa Piid p tev lt s hk asent...

Page 3: ...k ytt varten Niit sa suorittaa vain koulutuksen saanut henkil Tekniset tiedot Malli J nnite Virta Lukitun roottorin virta 3 1EVX 208 240 12 5 220V 60 220V 8400EJ 208 240 9 5 220V 40 220V 3 1EJ 208 240...

Page 4: ...n johdot ja liitokset Hartsin tulee ulottua noin 3 mm johdon kuoren p lle Huom Jos levit t liikaa hartsia ylij m saattaa joutua naarasliittimen sis n jolloin liittimet eiv t p se sulkeutumaan kunnolla...

Page 5: ...empi kellukkeen tuki 3 Pikaliitos kirkkaalla hartsilla Huomaa johdon kuorta peitt v m r KUUDES VAIHE Liu uta tiiviste ja mutteri kuoreen ja kirist mutteri Epoksin ei tarvitse antaa kuivua ennen kokoam...

Page 6: ...a 2 54 cm n galvanoitua putkea k ysien painoksi valinnainen D 7 16 11 mm hylsy ja r ikk 1 E 7 16 11 mm r ikk 1 F 9 16 14 mm hylsy ja r ikk 1 F 9 16 14 mm r ikk tai jakoavain 1 G Ruuvitaltta 1 Kokoamis...

Page 7: ...ja kirist kaikki 3 8 lukkomutterit 9 16 14 mm hylsyll ja r ik ll NELJ S VAIHE K nn kokoonpano ymp ri ja aseta alemmat kelluketuet osa B3 pulttien p lle pulttien kuuluisi ulottua kokoonpanon l pi Asenn...

Page 8: ...uuvaamalla se pumpun sis kartioon Kirist suutin alas saakka Kun asennat Redwood suutinta varmista ett Y osa osa D4 on asennettu suuttimeen asianmukaisesti Paina suutin kartio osan p lle sit t ytyy mah...

Page 9: ...a suuttimessa kartion sis ll merkint S k ytet n 3 8 x 2 5 pulttia VAIN 3 1EJF 3 3EHJF 5 3EHJF Malli HV Korkeus Leveys 3 1 3 3 3 4 6 m 3 0 m 5 3 5 5 8 m 3 0 m Linden suuttimessa laipan sis ll merkint L...

Page 10: ...vedess kuormitettuna J nnite Virta L1 L2 ____________ L1_______________ L1 L3 ____________ L2_______________ L2 L3 ____________ L3_______________ Virran ei tule vaihdella yli 5 t ydell kuormalla 3 va...

Page 11: ...ja tai siimaa on kietoutunut moottorin akselin ymp rille Vaikka Kasco suihkul hteet kuuluvat markkinoiden tukkiutumattomimpiin ei ole mahdollista est kaikkien aineiden p sy laitteeseen niin kauan kuin...

Page 12: ...olmen vuoden v lein moottori saattaa kest kauemmin ja s st kalliit korjauskulut L mp isemmill alueilla miss laite on k yt ss suurimman osan vuotta tiivisteet kannattaa vaihtaa s nn llisemmin kuin kylm...

Page 13: ...Irrota laite verkkovirrasta Tarkista onko potkuri tai siipiratas lohkeillut tai vaurioitunut mist syyst se ei toimi asianmukaisesti Lue kokoonpanon asennusohjeet Vaihda potkuri tai siipipy r jos se on...

Page 14: ...14 Kasco Marine Inc 800 Deere Rd Prescott WI 54021 U S A Puh 00 1 715 262 4488 Faksi 00 1 715 262 4487 www kascomarine com sales kascomarine com 884152...

Page 15: ...g3 Utility requirements pg3 Quick Disconnect Installation pg3 Wire Sizing Gland Sizing pg5 Parts Included pg6 Assembly Instructions pg6 EVX Pattern Size Chart pg8 J Nozzle Options pg8 3 Phase Startup...

Page 16: ...ire a startup test after wiring to ensure proper rotation of the impeller If the impeller is rotating in the opposite direction the unit will not perform properly and internal damage to the unit may o...

Page 17: ...ould only be per formed by a trained person Unit Specs Model Voltage range Operating amps lock rotor amps 3 1EVX 208 240 12 5 220V 60 220V 8400EJ 208 240 9 5 220V 40 220V 3 1EJ 208 240 13 2 220V 60 22...

Page 18: ...of of the 2 part epoxy Then apply resin into the housing enough to cover the wires and contacts The resin should be about 3mm onto the cord jacket Note Adding too much resin may cause excess to be fo...

Page 19: ...e gland nut securely No drying time is needed for the epoxy before full assembly STEP SEVEN Once the two subassemblies have been completed they can be joined together Plug pin assembly into the socket...

Page 20: ...anized pipe for weighting ropes optional D 7 16 11mm Socket Wrench 1 E 7 16 11mm Wrench 1 F 9 16 14mm Socket Wrench 1 F 9 16 14mm Wrench or adjustable crescent wrench 1 G Flat head screw driver 1 Asse...

Page 21: ...ttom Screen Clips Part B13 over the bolts as shown The power cord can be slid under the bottom screen where two float sections come together before the Lock Nuts are replaced Replace the three inside...

Page 22: ...snugly into the molded socket Install the Nozzle by threading it into the inner cone of the pump Make sure to tighten the Nozzle all the way down To install the Redwood nozzle make sure the Y Insert...

Page 23: ...e Sequoia nozzle marked S on the inside of the cone uses the 3 8 x 2 5 bolt 3 1EJF 3 3E H JF 5 3E H JF ONLY Model HP Height Width 3 1 3 3 3 4 6 m 3 0 m 5 3 5 5 8 m 3 0 m The Linden nozzle marked L ins...

Page 24: ...__ L2 L3 ____________ L3_______________ Current unbalance should not exceed 5 at full load Installation Instructions STEP ONE Use the ropes to position the Unit in the desired loca tion in the pond la...

Page 25: ...materials can be very damaging to the equipment under continued operation and must be removed as soon as possible ALWAYS DISCONNECT POWER TO THE UNIT BEFORE ATTEMPTING TO REMOVE CLOGS WINTER STORAGE...

Page 26: ...of more expensive repairs In warmer climates where the equipment runs most or all of the year it is a good idea to replace seals more regularly than you would need to in colder climates where the unit...

Page 27: ...from electrical power Check the propeller Impeller for any chipping or damage that would cause the unit to not operate properly Refer to installation instructions for assembly Replace propeller impel...

Page 28: ...14 Kasco Marine Inc 800 Deere Rd Prescott WI 54021 U S A Phone 00 1 715 262 4488 Fax 00 1 715 262 4487 www kascomarine com sales kascomarine com 884152...

Reviews: