background image

SMALL EJ SERIES FOUNTAIN MANUAL

10

TROUBLESHOOTING TIPS

ALWAYS DISCONNECT EQUIPMENT FROM ELECTRICAL SOURCE BEFORE SERVICING

SERVICE SHOULD ONLY BE PERFORMED BY A QUALIFIED TECHNICIAN OR ELECTRICIAN

Ground fault/earth leakage protection (RCD) tripping 

Typically indicates electrical current is leaking to earth (ground).

• 

Consult a qualified service technician or electrician to address the issue.

Possible causes: 

•  Control panel damaged or defective ground fault protection device (RCD, GFI)

•  Water contamination in the motor unit or Electrical motor damage

•  Power cord damage or water leak at quick disconnect

Collect this information for the electrician:

•  How long until the RCD trips after resetting? 

•  Does the trip time vary or repeat the same interval of time?

•  Does it trip randomly or same time of day?

•  How many times has it tripped?

•  Any electrical problems in the area recently, or changes made to site wiring?

Unit appears to run slowly

Typically indicates low voltage to the motor or motor damage.

• 

Contact a qualified service technician or electrician to measure for proper voltage and motor amps 

while the motor is operating.  Voltage drop should be no more the 5% from power source to motor 

control panel.

Unit hums and will not start

Typically indicates a motor capacitor problem (single phase motor), a motor controller problem (3 

phase), or debris preventing the unit from starting. 

• 

Turn the unit off and disconnect from power source to prevent motor damage. 

•  Remove the equipment from the water and inspect for debris or damage.

•  Remove the debris and clean the equipment.

• 

If there is no debris in the unit and it will not start. Turn the unit off and contact a qualified service 

technician to address the issue.  

Unit cycles on/off by itself

Typically indicates the motor is overheating. The Motor overload (single phase motor) will automatically 

reset once cooled down and restart the motor.
Possible causes:  

• 

Low water level, build-up of material on motor can preventing heat dissipation, or debris around the 

motor shaft or propeller area creating excess motor loading. 

• 

Turn the unit off and disconnect from power source to prevent motor damage.

•  Remove the equipment from the water and inspect for debris or damage.

•  If there is a build-up on the unit and motor can, remove the debris and clean the equipment.

Unit flow/performance fluctuates

Typically indicates debris is clogging the unit and preventing water flow into the unit.

• 

Turn the unit off and disconnect from power source.

•  Remove the equipment from the water and inspect for debris or damage.

•  If there is build-up on the unit and motor can, remove the debris and clean the unit.

Back to Contents

Summary of Contents for 2400EJ

Page 1: ...TAIN MANUAL 1 MOVING WATER FORWARD SINCE 1968 Operation Maintenance Manual Document number 884151 Document version 2022 1 0 EJ SERIES FOUNTAIN 2400EJ 3400EJ 800 Deere Rd Prescott WI 54021 sales kascomarine com kascomarine com ...

Page 2: ...nch 11 32 wrench 7 16 socket TOOLS AND SUPPLIES NEEDED Safety First 2 Unit Specifications 2 Parts Included 3 Included Nozzles 4 Premium Nozzles Not Included 5 Assembly Instructions 6 Nozzle Installation 7 Installation Instructions 8 Maintenance Recommendations 9 Troubleshooting Tips 10 Warranty 11 Other Repairs 12 Repair Contact Form 13 ...

Page 3: ...ts NEVER run the unit out of water This will damage the equipment and pose a danger to the operator Use extreme caution around water especially cold water NEVER lift or drag the unit by the power cord Always use the ropes or mount to remove it from the water Do not use waders in deep water or in areas with drop offs drastic slopes or soft bottom material Do not use boats that tip easily for unit i...

Page 4: ... Pan Head Screw 4 251220 C 1 4 split washers 7 840537 D 1 4 3 4 OD Flat Washer 10 251300 E 1 4 20 x 1 3 4 Hex Head Bolt 3 475630 F Bottom Screen Section 3 361540 G 1 4 20 Nut 3 840536 H 8 nut 6 771034 I 8 flat washer 12 361543 J 8 x 3 4 screw 6 361545 K Mooring ropes not pictured 2 990700 L Cable ties not pictured 9 415038 Back to Contents ...

Page 5: ... 431230 Model Height Width 2400 3 2m 2 4m 3400 3 5m 2 4m Linden 431232 Model Height Width 2400 2 3m 6 7m 3400 2 7m 8 5m 431259 451126 431258 451100 Cypress 431236 Model Height Width 2400 1 8m 4 5m 3400 2 1m 5 5m Willow Model Height Width 2400 1 6m 5 2m 3400 1 9m 5 8m No nozzle installed Comes installed Back to Contents ...

Page 6: ... 3 4m 8 5m Magnolia 431325K Model Height Width 2400 2m 6 1m 3400 2 6m 8 8m Contact Kasco Marine at sales kascomarine com or your local distributor for order information Mahogany 431345K Model Height Width 2400 2 4m 5 5m 3400 3 2m 7 9m Mighty Oak 431335K Model Height Width 2400 2 1m 5 3m 3400 2 9m 7 9m Back to Contents ...

Page 7: ...SMALL EJ SERIES FOUNTAIN MANUAL 6 ASSEMBLY INSTRUCTIONS B C D I J I H Align power cord with this notch 1 2 3 4 5 6 G C D D E F Back to Contents ...

Page 8: ...ist to lock the 3 tabs into the nozzle plate NOZZLE INSTALLATION Twist the nozzle into place and insert the quick release pin into one of the holes in the nozzle base plate Quick release pin 1 2 1 2 Standard Nozzle Installation Premium Nozzle Installation Back to Contents ...

Page 9: ...condary weight Normal water level Low water level High water level Alternate Installation Correct anchoring Incorrect anchoring Mooring lines are proper length and taut between unit and anchors at least 3 feet from the float for every foot of water depth Mooring lines are too short or loose between unit and anchors Back to Contents ...

Page 10: ...t and clean the equipment regularly In all regions inspect and clean the equipment at least once a year It is easiest to clean the unit immediately after removing it from the water when the equipment is still wet If you use a power washer avoid hitting the mechanical seal area directly Unit Storage Store the equipment with the cage down if it is going to be out of the water for long periods of tim...

Page 11: ...l not start Typically indicates a motor capacitor problem single phase motor a motor controller problem 3 phase or debris preventing the unit from starting Turn the unit off and disconnect from power source to prevent motor damage Remove the equipment from the water and inspect for debris or damage Remove the debris and clean the equipment If there is no debris in the unit and it will not start Tu...

Page 12: ... warranty coverage has been established the unit may be sent to any Kasco authorized repair center for evaluation and repair Please call Kasco at 715 262 4488 prior to shipping to receive any updated information or a repair form or call to locate your nearest authorized repair center You can also email Kasco at sales kascomarine com Please include the repair form received from Kasco or your local ...

Page 13: ...pairs after we have evaluated the unit but before we perform the work We will repair the unit only if repair costs are under a dollar amount stated by the customer Example Please repair if total is under 150 00 before shipping charges All estimates that are rejected for repair will be destroyed unless otherwise directed by the customer If the customer would like the unit returned we will restore t...

Page 14: ...this unit used in a chemical treatment or wastewater application circle one Yes No Additional notes Kasco Marine 800 Deere Road Prescott WI 54021 Attn Repairs Kasco requires that all equipment sent for repair MUST be accompanied by this form and marked to Repairs attention Unit should be cleaned before shipping Kasco is NOT responsible for shipping damage accrued in return shipment It is the respo...