5
Fig 11
Check for orange oring
Fig 12
9. Upon installation of the assembled unit, connect
your LED light kit to your ield installed GFCI pro
-
tected outlet and timer.
Instructions For Mounting LED6125 and
LED6C11
Instructions for attaching brackets on the loat prior
to mounting the light ixtures on 2 HP or larger Kasco
units.
Parts needed:
•
Lower loat brackets (6)
• 3/8” washers (3)
Part 1
Part 2
5. Install the 1/4” Flat Washer, 1/4” Lock Washer and
1/4” Nut as shown in Figure 10. Tighten the nut until
snug using the 7/16” Wrench.
Fig 10
lat washer
lock washer
1/4” nut
6. Adjust the angle of the light as desired and tighten
the two brass thumb screws on the sides of the ixture
until snug. Do not over tighten. It is best to have all
three ixtures at the same angle.
7. Repeat steps 1 through 4 for the remaining ixtures.
Assembled light ixtures are pictured in Figure 4. Note
the orientation of the lights.
8. Connect each ixture cord to the power cord’s wa
-
terproof connectors.
Make sure the orange oring is installed on the plug
side of the waterproof connector.
If any are miss-
ing, check the packaging to see if any fell off during
shipping, or an extra oring was included if there is one
missing.
Hand tighten the waterproof connectors as shown in
Figure 11. Using a cable tie, tie the light kit power
cord to the loat opposite the fountain power cord.
This will keep the cord from being damaged by the
fountain and balance the unit properly.
Next, cable tie each ixture cord to the loat to protect
each ixture cord as shown in Figure 12.