![Karmann Colorado Operating Instructions Manual Download Page 49](http://html1.mh-extra.com/html/karmann/colorado/colorado_operating-instructions-manual_3518294049.webp)
Fuses in body
Automatic fuse 230 V
Automatic charger & battery
ELECTRICAL INSTALLATION
6-2
The fuses are in the technical space behind
the driver's seat
1 = Entry step
2 = Consumer circuit 1
3 = Consumer circuit 2
4 = Consumer circuit 3
5 = refrigator
6 = heating
7 = Duomatic control fuse
8 = Pump
9 = Permanent consumers with BW function
Always make sure that the external
connection is 220-230 V and is fitted
externally with an earth leakage circuit
breaker.
Caution
The Automatic charger (suitable for gel-type
battery) is located under or behind the
passenger seat, according to the layout.
When the engine is running, the starter and
body battery are charged in parallel by the
charger. When the engine has been switched
off, the battery isolating relay isolates the
starter battery from the body battery.
With a connection to the 230 V external
supply the body battery is always charged
first.
The refrigerator relay isolates the refrigerator
from the body battery once the engine has
been switched off.
Safeguards the supply of 230 V (see
equipment overview).
It is located under the seat bench.
Switch up: Power circuit closed
Switch down: Fault. If repair is necessary,
see annex to operating instructions.