Ulteriori informazioni su:
www.karmaitaliana.it
9
8
SLAVE MODE
If you use several identical pars, you can synchronize them also without using a
DMX controller. Connect the pars together in daisy chain using the IN and OUT
(8-9) sockets. Set all the fixtures on slave (SLAE) except for the first one. All pars
will operate like the first one.
DMX MODE
In a DMX 512 linking there are 512 channels available.
Each DMX fixture uses one or more channels to manage its functions. The user must
assign a starting address to each DMX fixture. This address will indicate the first
channel used on the controller. You have to plan the starting address choice in order
to avoid channels’ overlapping. Otherwise the fixture will not work correctly.
Example: If you need to connect 3 DMX fixtures, each with 10 channels, the first unit
is to be set on address 1, the second unit on address 11 and the third one on address
21. Anyway you can set the same starting address on more devices if you wish them
to operate in synchrony. The order of linking of the devices is not important and it
doesn’t affect on how the controller manages each of them.
The cable length should not be more than 100mts to avoid interferences with other
signals or electric devices. A terminator is often required at the end of a DMX system.
Please address to a technician or to your reseller for further information.
To enter in DMX mode, press the Mode(2) key until the indication “A001” appears on
the display. Select then the wished address through the keys UP/DOWN(3-4). For the
function related to each DMX channel, refer to the chart on page 10/11.
English