33
soon as possible.
●
The use of rubber gloves and chemical goggles are recommended when
working with batteries.
●
NEVER smoke or strike a match near the batteries.
●
Replace the batteries IMMEDIATELY if there are any cracks or leaks.
1.
Plug connecting to the controller
2.
-The positive (+) terminal is
connected with a
RED
wire
labelled with the letter [
A
])
-The negative (-) terminal is
connected with a
BLACK
wire
labelled with the letter [
B
])
3.
Plug connecting to the breaker.
Batteries of Blazer Series
6.6.1 Remove the Batteries
6.6.1.1 Use #3 Allen Key Wrench included in your KARMA Tool Kit to remove
the six screws on the battery casing in the back of the wheelchair.
(Figure 6-5)
6.6.1.2 Place the rear casing aside, and unplug the lighting
connectors.(Figure 6-6)
6.6.1.3 Unfasten the battery strap. (Figure 6-7)
6.6.1.4 Use #5 Allen Key Wrench and #13 Closed Spanner included in your
KARMA Tool Kit to remove the screws on the partition plate. (Figure
6-8)
Figure 6-5
Figure 6-6
Figure 6-7
Figure 6-8