background image

Kardia Standard User Manual 

/

 16

 

Using the vacuum unit, without the filter or the dust bag, 

will void the warranty. The unit should be used with a dust 
bag because this will stabilize the efficiency of the unit and 

reduce by 5 to 6 times the maintenance of your unit. This is 
due to its large filtration surface. Order replacement bags 

and filters on 

www.kardia.no

Motor brushes 

Beside the occasional external clean, it is recommended that 
the motor brushes are inspected after 500 hours of use to 
check for wear. Replace as necessary. This inspection should be 

carried out on average once every 3 to 5 years. Contact service 
for information about the correct time interval for this 
maintenance procedure. 

 

 

Summary of Contents for Standard V.102

Page 1: ...User Manual Kardia Standard V 102 ...

Page 2: ...rcuit breaker Residual current circuit breakers on all circuits Intended for use with exterior cabinet for electrical meter Allocated space for low voltage equipment Ventilator Balanced airflow of 120 liters per second Up to 90 heat recovery efficiency Central Vacuum 17 L capacity 7 AMP motor Installation kit Vacuum hose and complete set of brushes Cabinet LED lighting with sensor Pair of sliding ...

Page 3: ...Kardia Standard User Manual 2 Table of contents 1 Hot Water Heater 3 2 Central Vacuum 13 3 Ventilator 21 4 Electrical 34 5 Warranty 36 ...

Page 4: ...3 Hot Water Heater ...

Page 5: ...telligent technical solutions exclusive to OSO SAGA boasts class leading insulation capabilities resulting in considerable energy savings whilst maintaining a higher temperature than other tanks 75 C for unbeatable performance and more hot water in a smaller unit SAGA XPRESS makes hot water available 3 times faster than standard hot water heaters without increased energy consumption thanks to the ...

Page 6: ... upper water temperature reaches 70 C the upper heater will cut out and the lower heater will start until the full tank of water is at 70 C As hot water gets consumed the lower heater will start to heat up the cold water When a large quantity of hot water is used in a short period of time the upper heater starts again as the hot water heater gets filled with cold water ...

Page 7: ... growth To adjust the temperature 1 Disconnect the power supply 2 Remove the front covers 4 with a screwdriver 3 Adjust the temperatures on the thermostat 7 with a screwdriver 4 Fit the covers 4 before connecting the power supply Changing the temperature setting on the thermostats only affects the temperature of the water in the tank Temperature to the taps is adjusted using the mixer valve ...

Page 8: ...x Before any electrical work is carried out the power supply must be disconnected and secured against activation while the work is in progress Setting the mixer valve The temperature of the outgoing hot water from the tank to the taps in the home can be adjusted using the knob on the mixer valve To adjust the temperature A Turn the adjustable knob 1 all the way to B Then turn the knob towards to t...

Page 9: ...e Annual inspection of safety valve Open valve for 1 min by turning the knob 3 approx 90 degrees to the open position Visually check that the water is flowing freely to the drain YES OK Close the valve by turning the knob 3 a further 90 degrees to the closed position NO NOT OK Disconnect power supply shut off water supply Contact installer ...

Page 10: ...for stable water pressure inside the home The pressure reducing valve is adjusted according to the pressure in the expansion vessel Contact authorized installer The safety valve is worn or particles from impure water have become stuck between the membrane and the valve seat Try to flush the safety valve through with water Open valve approx 1 minute If the valve still leaks it must be replaced Cont...

Page 11: ...uthorized installer No hot water Power supply interrupted Verify that the fuse is on and that the earth breaker has not been tripped Thermostat has cut out Press the RESET button on the safety thermostat see User guide Heating element is defective Replace heating element Contact authorized installer Leak in hot water pipe Verify as follows a close the mixer valve b wait 2 3 hours c feel the mixer ...

Page 12: ...temperature on the mixer valve see User guide page 6 The thermostat is set at a low temperature Raise the temperature on the thermostat to 85 C see User guide page 6 Change from cold to hot water in taps Contact authorized installer Fuse earth breaker trips repeatedly Possible fault in the heater s electrical system Verify as follows a switch off the electrical supply b unscrew the cover c visuall...

Page 13: ...of fault Possible solution There is a delay before the hot water reaches the tap Long stretch of pipe from water heater to tap Fit circulation wire or heating cable to hot water pipe Or fit an auxiliary heater close to the tap Contact authorized installer ...

Page 14: ...13 Central Vacuum ...

Page 15: ... simple to keep your house clean Kardia have cooperated with Drainvac to deliver the best central vacuum system perfect for residential use Model 230v SE1007 Air Watts 700 Pressure 3880 mm H2O Airflow 315 m3 h Sound power level 58 dB Current 7 A Liters 17 L Size Ø30 x 58 cm ...

Page 16: ...tied and must be replaced A reduction in power may be caused by the bag being full The bag should normally be replaced every 2 to 4 months DO NOT CHANGE THE DUST BAG WHILE THE UNIT IS RUNNING Clean the filter whenever the dust bag is changed The filter can easily be cleaned in the washing machine but drying in the dryer is not recommended The filter must be COMPLETELY DRY before re use To avoid de...

Page 17: ...ce of your unit This is due to its large filtration surface Order replacement bags and filters on www kardia no Motor brushes Beside the occasional external clean it is recommended that the motor brushes are inspected after 500 hours of use to check for wear Replace as necessary This inspection should be carried out on average once every 3 to 5 years Contact service for information about the corre...

Page 18: ...ted to the unit Try to establish an electrical contact between the two terminals of the 24 volt circuit on the unit with a metal object e g a screwdriver If the unit starts a 24 volt wire is either cut or disconnected from one of the wall inlets If the unit won t start up after these steps the printed circuit is defective Unit won t shut down Check the 24 volt circuit as follows Disconnect one of ...

Page 19: ...signed for dry suction only Do not use on wet or moist surfaces Avoid suction of any flammable liquids or combustible materials gasoline fuel diesel hot debris flammable materials cigarettes ashes matches waste solvents paint or other or explosive materials that would cause harm to the vacuum unit Refrain from vacuuming drywall dust or baking flour as these may damage the vacuum unit Avoid sucking...

Page 20: ...ose clothing are kept away from any openings Never operate without the dust bag and or the filter being in place In the case of the power cord being damaged this must be replaced with a dedicated cord available only from an authorized local dealer distributor Never operate the vacuum unit with a damaged cord or plug Should the system not be operating properly or if it has been dropped or damaged i...

Page 21: ...Kardia Standard User Manual 20 ...

Page 22: ...21 Ventilator ...

Page 23: ...rn houses are built to be airtight and require balanced ventilation to ensure both fresh indoor air and to remove moisture The ventilation system also prevents damage to building elements caused by dampness Kardia includes an energy efficient ventilator with a high efficiency rotary exchanger which recovers energy from the exhaust air Type EC direct current motors ensure economical operation ...

Page 24: ...gain Choose the ventilation mode by pressing select the desired ventilation mode by pressing The ventilator should normally be set in Home mode Away mode should be used to save energy when the house is not occupied Use Boost mode when you require extra airflow 4 To ensure good air quality and moisture control the ventilator should not be turned off 5 To ensure good air quality and airflow the filt...

Page 25: ...rdered from www kardia no To change the filters 1 Turn off the ventilation unit by pressing and holding for 5 seconds 2 Unplug the power cord 3 Open the ventilation unit door 4 Remove the old filter 5 Clean the filter area with a damp cloth 6 Fit the new filter 7 Close the ventilation unit door 8 Plug in the power cord 9 Turn on the ventilation unit by pressing and holding for 5 seconds Operating ...

Page 26: ...s function depends on the control panel s interface Home page decreases the set temperature for supply air Menu page moves the cursor down Setting page decreases the value of the selected item Menu Enter The button s function depends on the control panel s interface Home page confirms changes to set temperature Menu page activates setting highlighted by the cursor Setting page confirms changes to ...

Page 27: ...r temperature Indicates the air temperature returning to the ventilator The temperature reading is for information only and cannot be adjusted 6 Supply air temperature Indicates the air temperature the ventilator is currently supplying The temperature reading is for information only and cannot be adjusted 7 Outdoor air temperature Indicates the outdoor air temperature entering the ventilator The t...

Page 28: ...due to increased shower or bath usage Temperature This option displays all the temperature readings CO2 levels humidity levels and PM2 5 levels Room humidity 1 Indicates the extract air humidity Room humidity 2 Indicates the supply air humidity Room PM2 5 1 Indicates the extract air PM2 5 level Room PM2 5 2 Indicates the supply air PM2 5 level Away mode Home mode Boost mode Room air temp 20 C Supp...

Page 29: ...000ppm Room CO2 100ppm PM2 5 set 100ug m PM2 5 15ug m Summer night cool Adjust in order to control whether dependent on conditions Summer night cool mode is to be switched on automatically Electric heater Adjust to control whether dependent on conditions the electric heater is to be switched on automatically Boost time Adjust to set the Boost mode duration Humidity set Adjust the humidity setting ...

Page 30: ...used to change the time and date displayed on the Home page 8 Timer All Sunday Monday Tuesday Wednesday Thursday Friday Saturday Timer 1 02 00 04 00 Timer 2 Timer 3 Timer 4 This option is used to set periodic schedules for the ventilator to switch to Boost mode automatically Input time for ventilator to switch to Boost mode and input time for ventilator to switch back to Home mode on each day of t...

Page 31: ...Summer mode when the indoor air temperature is over 22 C and the outdoor air temperature is below indoor air temperature and above 16 C The ventilator will increase fan speed to level 4 in order to cool the indoor air Summer cool recovery In Summer mode the heat exchanger will start when the indoor air is cooler than the outdoor air Frost prevention This function prevents the heat exchanger from f...

Page 32: ...ng is not correct please contact service or a qualified installer Unit is too noisy The ventilation unit is designed to operate at an acceptable noise level during continuous operation If you have been used to living in a house without balanced ventilation you may notice a slight humming noise from the unit If you notice irregular sounds or a higher noise level from the unit it may be because of c...

Page 33: ...he unit and press both red buttons on the heater Heater malfunction contact service Supply air temperature is too high Sensor defect Deactivate pre heater in User settings contact service Control panel shows Room temp error Supply temp error Outdoor temp error Extract temp error Exhaust temp error Excess temp error Frost temp error Humidity sensor error The ventilator is not receiving a signal fro...

Page 34: ...ed from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of technical knowledge provided they are supervised or have been given instruction concerning the safe operation of the appliance and are aware of the dangers involved Children must not play with the appliance Cleaning and user maintenance shall not be carried out by children unless supervised ...

Page 35: ...Kardia Standard User Manual 34 ...

Page 36: ...35 Electrical ...

Page 37: ...4 The electrical panel also contains an area for low voltage equipment All electrical servicing must be carried out by a qualified electrician For best performance wireless internet routers should not be placed inside the Kardia unit ...

Page 38: ...d An additional guarantee period can be provided depending on applicable country laws or the terms of the commercial sales contract General warranty limitations The warranty is only valid if the instructions in this manual are followed In the case of the guidelines and instructions being ignored the warranty will be voided ...

Page 39: ...er should agree to salvaging any obsolete equipment free of charge We recommend that you inform your supplier that you want them to salvage your unit at the same time as you order and replace it with a new one Do not discard the unit together with your regular garbage The symbol representing a garbage bin on wheels on the unit s label Figure C attests to this requirement You must ensure that at th...

Page 40: ...Switchboard 47 64 86 50 00 Email contact kardia no www kardia no ...

Reviews: