You need to use the matching high-pres-
sure nozzles to ensure that your high-pres-
sure cleaner works properly.
Note:
Nominal pressure (p): See Operating
Instructions or type plate of your high-pres-
sure cleaner.
e.g.: K 6 – K 7, Kärcher 600 – Kärcher 770
Î
Use yellow high-pressure nozzles.
Note:
The yellow high-pressure nozzles
have already been installed.
eg: K 2 – K 5, Kärcher 201 – Kärcher 560
Î
Use grey high-pressure nozzles.
Illustrations on fold-out page!
Î
Illustration
1 Loosen the safety clamp with a screw-
driver.
2 Remove the protective grid.
3 Remove the clip.
4 Pull out the yellow high-pressure noz-
zle.
5 Insert the grey high-pressure nozzle.
6 Re-insert the clip.
7 Mount the protective grid on the pin.
8 Push the safety clamp in until it locks.
Note
: Always use Kärcher water filter (or-
der no. 4.730-059.0) during suction opera-
tions of the high-pressure cleaner.
Fasten the T-Racer to the high-pressure
gun using the extension pipes.
Î
Illustration
1 Press the extension pipe into the bayo-
net catch of the T-Racer.
2 Turn it by 90° until it locks into place.
3 Tighten the safety cover.
–
Repeat this process even for the other
joints.
Outdoor surfaces should be swept be-
fore the T-Racer is used to avoid dam-
aging the high-pressure nozzles.
The T-Racer is not suited for scouring
or scrubbing!
Caution
Î
Illustration
Do not run over free-standing corners!
Fasten the T-Racer directly to the high-
pressure gun.
Î
Illustration
1 Press the bayonet connection of the T-
Racer into the connection of the high-
pressure gun.
2 Turn it by 90° until it locks into place.
3 Tighten the safety cover.
Caution
Î
Illustration
Always hold the T-Racer at the handle
while cleaning the walls.
Preparing the Appliance
Selecting the high-pressure nozzles
High-pressure cleaner with nominal
pressure (p) of 13 MPa (130 bar) to 16
MPa (160 bar)
High-pressure cleaner with nominal
voltage (p) lesser than 13 MPa (130 bar)
Changing the high-pressure nozzles
Application
Cleaning floor surfaces
Tips for cleaning