Technical data

Subject to technical modifications.

Optimising the flow rate

The flow rate is further increased:

The lifting height is reduced.

The diameter of the hose used is increased.

The length of the hose used is decreased.

The smaller the pressure loss caused by the con-
nected up accessories.

Declaration of Conformity

We hereby declare that the machine described below 
complies with the relevant basic safety and health re-
quirements in the EU Directives, both in its basic design 
and construction as well as in the version placed in cir-
culation by us. This declaration is invalidated by any 
changes made to the machine that are not approved by 
us.
Product: Pump
Type: 1.645-xxx

Currently applicable EU Directives

2014/35/EU
2014/30/EU
2011/65/EU
2009/125/EC

Commission Regulation(s)

(EU) 2019/1781

The pump does not start 
up, or stops suddenly 
during operation

The power supply is disconnected.

1. Check the fuses and the electrical connec-

tions.

The thermal protection switch has 
switched off the pump because of over-
heating.

1. Pull the mains plug out of the socket.
2. Allow the pump to cool down.
3. Remove any dirt particles in the suction ar-

ea.

4. Clean the suction area.
5. Prevent the pump from running dry.

Dirt particles block the suction area.

1. Pull the mains plug out of the socket.
2. Clean the suction area.

The pumping capacity 
decreases

The suction area is clogged.

1. Pull the mains plug out of the socket.
2. Clean the suction area.

The delivery rate is too 
low

The maximum delivery head is exceed-
ed.
The hose diameter and the hose length 
have been selected incorrectly.

1. Observe the maximum delivery head, see 

chapter 

 Technical data

.

2. If necessary, select a greater hose diame-

ter or a shorter hose length, see chapter 

 

Optimising the flow rate

.

Quick-Connect cannot 
be opened or closed

The push-fit system is dirty.

1. Remove the clip.
2. Clean the clip.
3. Install the clip.

Fault

Cause

Rectification

SP 
16.000 
Dirt

SP 
22.000 
Dirt

Device performance data

Mains voltage

V

230-240 230-240

Power frequency

Hz

50

50

Nominal power

W

550

750

Maximum flow rate

l/h

16.000

22.000

Pressure (max.)

MPa 
(bar)

0,08 
(0,8)

0,08 
(0,8)

Delivery height (max.)

m

8

8

Immersion depth (max.)

m

7

7

Perm. temp. feed fluid

°C

5...35

5...35

Particle size (max.) of per-
missible feed fluids

mm

20

30

Minimum fluid level (manu-
al mode)

mm

60

50

Residual fluid height

mm

25

35

Weight (without accesso-
ries)

kg

4,9

6,5

EU Declaration of Conformity

Summary of Contents for SP 16.000 Dirt

Page 1: ...SP 16 000 Dirt SP 22 000 Dirt 5 991 079 0 09 22 English 4 10...

Page 2: ...A...

Page 3: ...B C D E F G H...

Page 4: ...pproved according to the Austrian Electro technical Association standard VE B EN 60555 Parts 1 to 3 where the nominal secondary output volt age of the transformer must not exceed 230 V Only operate th...

Page 5: ...onmental protection The packing materials can be recycled Please dispose of packaging in accordance with the en vironmental regulations Electrical and electronic appliances contain valu able recyclabl...

Page 6: ...d ground in the pumped liquid or immerse it via a rope attached to the carrying handle Note The suction area must not be blocked by soiling If the ground is muddy place the pump on a brick or similar...

Page 7: ...ins plug out of the socket 3 Press the Quick Connect button and remove the connection nozzle Illustration C 4 Where necessary remove residue from the hose and on Quick Connect 5 Clean the outside of t...

Page 8: ...down 3 Remove any dirt particles in the suction ar ea 4 Clean the suction area 5 Prevent the pump from running dry Dirt particles block the suction area 1 Pull the mains plug out of the socket 2 Clea...

Page 9: ...well as in the version put into circulation by us This declaration shall cease to be valid if the product is modified without our prior approval Product Pump Type 1 645 xxx Currently applicable UK Re...

Page 10: ...14 SP 16 000 Dirt SP 22 000 Dirt V 230 240 230 240 Hz 50 50 W 550 750 l h 16 000 22 000 MPa bar 0 08 0 8 0 08 0 8 m 8 8 m 7 7 5 35 5 35 mm 20 30 mm 60 50 mm 25 35 kg 4 9 6 5...

Page 11: ...13 1 2 3 C 4 5 6 1 2 1 2 3 1 1 2 1 1 1 2 3 4 5 1 2 1 2 1 2 1 2 3...

Page 12: ...G 1 5 C 1 D 2 1 E 1 F 2 5 G 2 2 5 60 SP 16 000 Dirt 50 SP 22 000 Dirt 25 SP 16 000 Dirt 35 SP 22 000 Dirt 1 H 2 1 2 3 SP 16 000 Dirt SP 22 000 Dirt 18 21 20 24 4 12 6 15 SP 16 000 Dirt SP 22 000 Dirt...

Page 13: ...kaercher com REACH www kaercher com A 1 2 3 4 5 G1 1 1 1 G1 6 G1 7 8 9 10 G 1 1 G 1 11 12 SP 16 000 Dirt G1 13 SP 22 000 Dirt 1 SP 16 000 Dirt SP 22 000 Dirt G1 G 1 1 1 1 G1 G 1 1 1 1 G 1 1 B 2 3 G1...

Page 14: ...10 30 1 3 VE B EN 60555 VE 230 30 60 10 10 11 11 11 11 11 11 12 12 13 13 13 14...

Page 15: ......

Page 16: ...e uns Ihre Meinung Rate your product and tell us your opinion valuer votre produit et dites nous votre opinion Rese e su producto y d ganos su opini n www kaercher com welcome www kaercher com dealers...

Reviews: