Caution

Make sure that the power cable or ex-
tension cables are not damaged by run-
ning over, pinching, dragging or similar. 
Protect the power cable from heat, oil, 
and sharp edges.

Never fill solvents, solvent-containing 
liquids or undiluted acids (e.g. deter-
gents, benzene, paint thinner, and ace-
tone) into the water reservoir as these 
substances affect the materials used on 
the appliance.

The appliance must not be carried dur-
ing cleaning.

The appliance must provide of a stable 
ground.

Use and store the unit only in accord-
ance with the specifications in the de-
scription and/or figure.

The steam switch must not be locked 
during the operation.

Protect the appliance from rain. Do not 
store outside.

Caution

Safety devices protect the user and must 
not be modified or bypassed.

The pressure controller keeps the boiler 
pressure during the operation as constant 
as possible. The heating is turned off if the 
maximum operating pressure of 4 bar is 
reached in the boiler and is reactivated in 
case of a pressure drop in the boiler due to 
steam tapping.

If, in case of a malfunction, there is no wa-
ter in the boiler, the temperature in the boil-
er rises. The boiler thermostat turns off the 
heating. Once the boiler is filled, normal op-
eration can continue.

The safety thermostat turns off the appli-
ance if the boiler thermostat and the pres-
sure controller fails and the appliance 
overheats in case of a malfunction. Please 
contact your local KÄRCHER customer 
service to arrange for the reset of the safety 
thermostat.

The maintenance lock acts as a pressure 
control valve at the same time. It seals the 
boiler against the steam pressure that 
builds up in the boiler. 
If the pressure controller is defect and the 
steam pressure in the boiler rises, the pres-
sure control valve, and steam is emitted 
through the maintenance lock to the out-
side. 
Please contact your local KÄRCHER cus-
tomer service before you put the appliance 
into operation again.

Safety Devices

Pressure controller

Boiler thermostat

Safety thermostat

Maintenance lock

All manuals and user guides at all-guides.com

Summary of Contents for SC 2.500 C

Page 1: ...ng Instructions Before first use of the unit read these operating instructions and act in accordance with them 59659680 01 13 SC 2 500 C All manuals and user guides at all guides com a l l g u i d e s...

Page 2: ...escription of the Appliance 6 Quick Reference 7 Operation 8 How to Use the Accessories 10 Maintenance and care 12 Troubleshooting 13 Customer service 13 Technical specifications 14 Special accessories...

Page 3: ...proper recycling of old appliances Please dispose your old appli ances using appropriate collection sys tems Notes about the ingredients REACH You will find current information about the ingredients...

Page 4: ...ance may only be connected to an electrical supply which has been installed in accordance with IEC 60364 The appliance may only be connected to alternating current The voltage must correspond with the...

Page 5: ...of 4 bar is reached in the boiler and is reactivated in case of a pressure drop in the boiler due to steam tapping If in case of a malfunction there is no wa ter in the boiler the temperature in the b...

Page 6: ...nection cable A12 Storage holder for floor nozzle A13 Mains cable with mains plug A14 Running wheels 2 ea A15 Steering roller B1 Steam gun B2 Steam lever B3 Unlocking button B4 Selector switch for the...

Page 7: ...ain plug Turn on the appliance 3 Indicator lamp heating on is blinking green Wait until the indicator lamp heater lights up permanently 4 Connect the accessories to the steam gun The steam cleaner is...

Page 8: ...8 English Operation All manuals and user guides at all guides com...

Page 9: ...ain water Illustration You can remove the water reservoir to fill it or you can fill it directly on the appliance Pull the water reservoir straight up Fill the water reservoir up to the MAX marking wh...

Page 10: ...ion Steam at first then let dry and then check for colour or shape changes When cleaning painted or plastic coated surfaces as found on kitchen and living room furniture doors parquet wax furni ture p...

Page 11: ...alcium and soap residues in the bath room for e g shower cabins tiled walls Can be washed at 60 C please do not use any fabric softener Not suitable for drier Note Detergent residue or care emulsions...

Page 12: ...cifier sticks order no 6 295 047 to decalcify the water Please follow the dosing instruc tions on the packaging while using the decalcifying solution Caution Use caution when filling and emptying the...

Page 13: ...n on the appliance Water reservoir has not been inserted prop erly or is calcified Remove the water reservoir and rinse it Insert the water reservoir and press downwards until it arrests Steam switch...

Page 14: ...surfaces Microfibre cloth set soft floor 2 863 173 2 soft floor cloths made of velvet velour Microfibre cloth set soft cover2 863 174 2 soft covers made of plush velour Terry cloth rags 6 369 357 5 f...

Page 15: ...English 15 Spare Parts All manuals and user guides at all guides com...

Page 16: ...www karcher co nz www karcher com au All manuals and user guides at all guides com a l l g u i d e s c o m...

Reviews: