background image

6

DANGER

Danger of electric shock

Risk of injury and damage.
The socket is only intended for the direct
connection of the PW 30/1 additional brush
washer head to the Puzzi 10/2 Adv. Any
other use of the socket is prohibited.

Switching on the device

1. Connect the mains plug.
2. Press the suction switch to switch on the 

suction turbine.

3. Press the spray switch to switch on the

spray pump.

Cleaning mode

ATTENTION

Danger from cleaning solution

Risk of damage
Before using the device, check the object to 
be cleaned for colour fastness and water 
resistance in an inconspicuous place.

1. Press the lever on the angle piece to

spray the cleaning solution.

2. Run over the surface to be cleaned in

overlapping paths. Pull the nozzle back-
wards (do not push).

3. When work is interrupted, the floor noz-

zle can placed in the device carrying
handle.

Switching off the device

1. Switch off the spray switch and the suc-

tion switch.

2. Pull out the mains plug.

Empty the wastewater container

1. Switch off the suction switch and the

spray switch when the wastewater con-
tainer is full.

2. Remove the cover.
3. Remove the wastewater container from

the device and empty it.

Emptying the fresh water tank

1. Switch off the device.
2. Briefly operate the lever on the angle

piece to relieve pressure.

3. Disconnect the angle piece from the

spray / suction hose.

4. Hang the suction hose in the fresh water 

tank.

5. Press the suction switch to switch on the 

suction turbine.

6. Suck the fresh water tank empty and

switch off the device.

7. Remove the cover.
8. Remove the wastewater container from

the device and empty it.

Flushing the device

1. Connect the angle piece (with suction

pipe and floor nozzle) to the suction
hose.

2. Connect the spray hose coupling to the

angle piece and latch into place.

3. Pour approximately 2 litres of tap water

into the fresh water tank. Do not add de-
tergents.

4. Press the spray switch to switch on the

spray pump.

5. Hold the floor nozzle over a drain.
6. Operate the lever on the angle piece and

flush the device for 1 to 2 minutes.

7. Switch off the device.

Each time after use

1. Flush the device.
2. Drain the wastewater container and

clean it under running water.

3. Empty the fresh water tank.
4. Clean the exterior of the device with a

damp cloth.

5. To avoid unpleasant smells, remove all

water from the device before long down-
times.

6. Let the device dry thoroughly: Remove

the cover or move it to the side.

Storing the device

1. Store the device in a dry room and se-

cure it against unauthorised use.

Cleaning methods

Normal soiling

1. Spray and vacuum up the cleaning solu-

tion in one step.

Note

Repeated vacuuming without spraying 
shortens the drying time.

Summary of Contents for Puzzi 10/2 ADV

Page 1: ...CARPET UPHOLSTERY CLEANER 240V Model Puzzi 10 2 ADV Product Code 14 1411 59692350 01 20 001 3...

Page 2: ...1 2 3 4 5 7 1 2 CHEM MAX 50 C MAX 6 8 9 CHEM MAX 2L 1 2 A 1...

Page 3: ...16 29 6 12 17 25 24 26 23 7 10 27 34 35 36 33 1 2 3 4 5 11 15 13 18 21 14 20 22 28 19 8 9 30 31 32 B 2...

Page 4: ...C 3...

Page 5: ...on content materials can be found at www kaercher com REACH Intended use This spray retraction device is intended for wet cleaning of carpets This device is suitable for commercial use e g in hotels...

Page 6: ...Connect the suction hose to the angle piece Connect the spray hose coupling to the angle piece and latch into place Mixing the cleaning solution DANGER Danger from detergents Risk of injury and damag...

Page 7: ...the lever on the angle piece to relieve pressure 3 Disconnect the angle piece from the spray suction hose 4 Hang the suction hose in the fresh water tank 5 Press the suction switch to switch on the s...

Page 8: ...ned ar ea until after it has fully dried Detergent For further information please request the product information sheet and the EU safe ty data sheet for the relevant cleaning agent Transport CAUTION...

Page 9: ...ountries We shall remedy possible malfunctions on your appliance within the warranty period free of cost provided that a material or manufacturing defect is the cause In a war ranty case please contac...

Page 10: ...uantity max l s 74 Vacuum max kPa mbar 25 4 254 Spray pressure MPa 0 2 Spray pressure max MPa 0 3 Spray volume l min 2 Cleaning solution temperature max C 50 Dimensions and weights Typical operating w...

Page 11: ...Accessories 4 762 014 0 Hard surface adapter 240 4 130 001 0 DN 32 110 4 130 010 0 DN 32 0 25 5 070 010 0 Container for detergent 6 980 078 0 DN 20 26 6 980 077 0 6 980 080 0 10...