background image

8.913-995.0 • Landa PC • Rev. 03/20

9

 

PRESSURE WASHER 

    

OPERATOR’S MANUAL

  

STEP 1:

 Check engine oil level. Oil level should be 

level with the bottom of the oil filler neck. Be sure the 
machine is level when checking the oil level. (Refer to 
the engine's operating manual included with machine.) 
We recommend that the oil be changed after the first 5 
hours of use, then once every 50 hours. 

Note:

 Improper 

oil levels will cause low oil sensor to shut off engine.  

IMPORTANT! Do not run engine with high or low 

oil levels as this will cause engine damage.

STEP 2:

 Remove shipping cap and install oil dipstick. 

Check pump oil level by using dipstick or observe oil 
level in oil window (if equipped).  

Use 30 wt. (non 

detergent) oil.

STEP 5:

 Rotate the fuel shut-off valve to the "On" 

position. Slide the fuel valve lever to the "ON" position.  
When the engine is not in use, leave the fuel valve in 
the "OFF" position.

STEP 4:

 Trigger the spray gun to eliminate trapped air 

then wait for a steady flow of water to emerge from 
the spray nozzle.

OPERATING INSTRUCTIONS

STEP 3:

 Fill gas tank with unleaded gasoline. Do not 

use leaded gasoline.

STEP 6:  

Move the choke lever to the "Choke" posi-

tion (on a warm engine, leave the choke lever in the 
run position).  Move the choke lever to the "Closed" 
position.  To restart a warm engine, leave the choke 
lever in the "Open" position.

Oil Dipstick

Dipstick

Oil Window

Gas  

Tank

Choke 

Lever

Fuel 

Valve

Choke

Fuel 

Valve

Summary of Contents for Landa PC3-2400

Page 1: ...L LO W EN GIN E ST OP S IM ME DIA TE LY RE AD OW NE R S MA NU AL BE FO RE OP ER AT IO N LIR E LE MA NU EL D U TIL ISA TE UR AV AN T US AG E VO R IN BE TR IEB NA HM E UN BE DI NG T BE DI EN UN GS AN L...

Page 2: ......

Page 3: ...to the pressure washer You should record both serial number and date of purchase and keep in a safe place for future reference Important Safety Information 4 6 Component Identification 7 Assembly Inst...

Page 4: ...All installations must comply with local codes Contact your electrician plumber utility company or the selling distributor for specific details WARNING RISK OF ASPHYXIATION USE THIS PRODUCT ONLY IN A...

Page 5: ...SEVERE INJURY TO PERSONS KEEP CLEAR OF NOZZLE WARNING WARNING High pressure de veloped by these machines will cause personal injury or equip ment damage Keep clear of nozzle Use caution when op erati...

Page 6: ...y cool down or maintain the heating coil may result in a steam explosion 26 In oil burning models use only kerosene No 1 home heating fuel or diesel If diesel is used add a soot remover to every tankf...

Page 7: ...e end to water pump discharge nipple and the other end to spray gun Pump Protector Cycles fresh cool water through pump when recirculating water reaches 140 F Note If trigger on spray gun is released...

Page 8: ...seated properly STEP 8 Connect the high pres sure hose to the pump discharge nipple Push coupler collar forward until secure STEP 5 Attach nozzle extension to spray gun wand Tighten both by hand STEP...

Page 9: ...il level by using dipstick or observe oil level in oil window if equipped Use 30 wt non detergent oil STEP 5 Rotate the fuel shut off valve to the On position Slide the fuel valve lever to the ON posi...

Page 10: ...throttle to fast position CAUTION Small engines may kick back Do not hold pull starter grip tightly in hand OPERATING INSTRUCTIONS CON T WARNING Never replace nozzles without engaging the safety latch...

Page 11: ...ith fresh water Place de tergent suction tube directly into cleaning solution and apply to surface at low pressure for best results limit your work area to sections approximately 6 feet square and alw...

Page 12: ...is not being operated or is being stored for more than one month follow these instructions 1 Replenish engine oil to upper level 2 Drain gasoline from fuel tank fuel line fuel valve and carburetor 3...

Page 13: ...valves Contact local dealer Nozzle is obstructed Blow out or remove debris with fine needle Pump sucking air inlet hose leaking Check all pump lines and connections PRESSURE LOW AFTER PERIOD OF NORMA...

Page 14: ...of 50 garden hose NO DETERGENT Detergent suction tube not properly connected to machine Check connection Detergent is too thick Dilute detergent For best results use manufac turers detergent Detergent...

Page 15: ...en under severe conditions MAINTENANCE SCHEDULE Engine Oil SAE 10W 30 Inspect Daily Change First month or 20 hours Every 100 hours or every 6 months after first month Filter Every 50 hours Air Cleaner...

Page 16: ...324 Only 4 9 104 030 0 Quick connect nozzle Kit 040 35324 1 9 802 296 0 Nozzle 0015 Yellow 1 9 802 297 0 Nozzle 0025 Green 1 8 932 298 0 Nozzle 0040 White 1 4 8 904 154 0 Quick Connect Nozzle Kit 035...

Page 17: ...Power Washer Change pump oil after first 50 hours every year or 500 hours thereafter Use SAE 10W 40 non foaming Engine oil Check daily before first use of your new Power Washer Change engine oil afte...

Page 18: ...e center field labor charges or freight damage WHAT YOU MUST DO TO OBTAIN WARRANTY SERVICE While not required for warranty service we request that you register your LANDA pressure washer by returning...

Page 19: ...Form 8 913 995 0 Landa PC Revised 03 20 Printed in U S A or Mexico...

Reviews: