English
11
Subject to technical changes.
We hereby declare that the machine described below
complies with the relevant basic safety and health re-
quirements of the EU Directives, both in its basic design
and construction as well as in the version put into circu-
lation by us. This declaration shall cease to be valid if
the machine is modified without our prior approval.
The signatories act on behalf of and with the authority of
the company management.
Documentation supervisor:
S. Reiser
Alfred Kärcher SE & Co. KG
Alfred-Kärcher-Straße 28-40
71364 Winnenden (Germany)
Tel.: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2018/08/01
Technical specifications
Device
Battery pack nominal voltage
18 V =
Protective class
III
Operating time when battery fully
charged (max.)
10 min
Water connection
Max. feed temperature
40 °C
Max. feed pressure
1,0 MPa
Performance data
Max. permissible pressure
2,4 MPa
Values determined as per EN 60335-2-79
Hand-arm vibration value
Uncertainty K
1,3
0,6
m/s
2
m/s
2
Sound pressure level L
pA
Uncertainty K
pA
74
3
dB(A)
dB(A)
Sound power level L
WA
+ Uncertainty
K
WA
89 dB(A)
Battery Power 18/25
Battery type
Li-Ion
Battery pack nominal voltage
18 V =
Rated capacity
(according to IEC/EN 61690)
2,4 Ah
Rated capacity
(according to specifications of cell
manufacturer)
2,5 Ah
Rating (in accordance with UN 3480)
43,2 Wh
Max. charging current
3,5 A
Operating temperature
-20...40 °C
Charging temperature
0...40 °C
Storage temperature
-20...60 °C
Weight
0,5 kg
Dimensions (L x W x H)
133 x 88
x 50 mm
Standard charger Battery Power 18 V
Nominal voltage
100-240 V
Frequency
50-60 Hz
Power input (max.)
0,3 A
Protective class
II
Battery pack nominal voltage
18 V =
Charging power (max.)
0,5 A
Charging time (for an empty battery
pack) approx.
4 h
Weight (without battery pack)
0,16 kg
EU Declaration of Conformity
Product:
Pressure cleaner (battery powered)
Type:
1.328-1xx
Relevant EU Directives
2014/35/EU
2014/30/EU
2011/65/EU
2000/14/EC
Applied harmonized standards
EN 60335–1
EN 60335-2-29
EN 60335–2–54
EN 62233: 2008
EN 55014–1:2017
EN 55014–2: 2015
EN 61000–3–2: 2014
EN 61000–3–3: 2013
EN 50581
Applied conformity evaluation method
2000/14/EC: Appendix V
Sound power level dB(A)
Measured:
86
Guaranteed:
89
Chairman of the Board of Management
Director Regulatory Affairs & Certification
Summary of Contents for KHB 5 Battery
Page 2: ...2 see Illustration H...