DANGER

Risk of electric shock.

Never touch the mains plug 

and the socket with wet 

hands.

Check the power cord with 

mains plug for damage prior 

to every use. Immediately 

have damaged power cord 

replaced by an authorised 

customer service / electrician. 

Do not operate an appliance if 

the power cord is damaged.

All current-conducting parts 

in the working area must be 

protected against jet water.

The mains plug and the cou-

pling of an extension cable 

must be watertight and must 

never lie in water. Moreover, 

the coupling may never lie on 

the ground. The use of cable 

reels that ensure that the 

sockets are at least 60 mm 

above the ground is recom-

mended.

Make sure that the power 

cord or extension cable is not 

damaged by running over, 

pinching, dragging or the like. 

Protect the power cords from 

heat, oil, and sharp edges.

Turn off the appliance and re-

move the mains plug prior to 

any care and maintenance 

works.

Repair work and work on the 

electrical components may 

only be performed by an au-

thorised customer service.

WARNING

The appliance may only be 

connected to an electric sup-

ply that has been installed by 

an electrician in accordance 

with IEC 60364.

The appliance may only be 

connected to alternating cur-

rent. The voltage must corre-

spond with the type plate of 

the appliance.

Safety class I - Appliances 

may only be connected to 

sockets with proper earthing. 

For safety reasons, we rec-

ommend that you operate the 

appliance only via a residual 

current device (max. 30 mA).

An unsuitable electrical ex-

tension cable can be hazard-

ous. Only use an electrical 

extension cable which has 

been approved and labelled 

for this purpose and has an 

adequate cable cross-section 

outdoors: 1 - 10 m: 1.5 mm

2

10 - 30 m: 2.5 mm

2

Always fully unreel the exten-

sion cable from the cable 

drum.

DANGER

The user must use the appli-

ance as intended. The person 

must consider the local condi-

tions and must pay attention 

to other persons in the vicinity 

when working with the appli-

ance.

Electric components

Safe handling

 

 

 

Summary of Contents for K 7 Compact

Page 1: ...K 7 Premium Full Control Operating Instructions Please read the operating instructions carefully before using the unit 59658110 12 15 ...

Page 2: ...2 ...

Page 3: ...3 ...

Page 4: ...leads to severe injuries or death 몇 WARNING Pointer to a possibly dangerous situation which can lead to se vere injuries or death 몇 CAUTION Pointer to a possibly dangerous situation which can lead to mi nor injuries ATTENTION Pointer to a possibly dangerous situation which can lead to property damage Contents Safety instructions 4 Description of the Appliance 9 Scope of delivery 9 Proper use 9 Env...

Page 5: ...intenance works Repair work and work on the electrical components may only be performed by an au thorised customer service 몇 WARNING The appliance may only be connected to an electric sup ply that has been installed by an electrician in accordance with IEC 60364 The appliance may only be connected to alternating cur rent The voltage must corre spond with the type plate of the appliance Safety clas...

Page 6: ...rated by children or per sons who have not been in structed accordingly This appliance is not intended for use by persons with limit ed physical sensory or men tal capacities or lacking expe rience and or skills unless such persons are accompa nied and supervised by a per son in charge of their safety or they have received precise instructions on the use of this appliance and have under stood the ...

Page 7: ...Type BA Water that has flown through a system separator is no longer classified as drinking water High pressure hoses fixtures and couplings are important for the safety of the appli ance Only use high pressure hoses fixtures and couplings recommended by the manu facturer When disconnecting the sup ply or high pressure hose hot water may leak from the con nections after operation 몇 CAUTION Mind th...

Page 8: ...res sure cleaners aerosols can develop Inhaling aerosols can cause health damage Depending on the applica tion completely shielded noz zles e g surface cleaner that significantly reduce the emission of aqueous aero sols can be used for high pressure cleaning The use of such shielding is not possible with all applica tions If the use of a completely shielded nozzle is not possi ble a respirator of ...

Page 9: ...ransport damage please contact your dealer Fabric reinforced water hose with commercially available coupling Minimum diameter 1 2 inches 13 mm Minimum length 7 5 m Use this pressure washer for private households only for cleaning machines vehicles buildings tools facades terraces gardening tools etc by means of a high pressure water jet if necessary with ad ditional cleaning agents with accessorie...

Page 10: ...trigger gun without bubbles Release the lever of the trigger gun Lock the lever of the trigger gun ATTENTION Dry running of more than 2 minutes leads to damage of the high pressure pump If the appliance does not build up pressure within 2 minutes switch the appliance off and proceed in accordance with the instructions in Chapter Troubleshooting 몇 CAUTION Keep a distance of at least 30 cm when usin...

Page 11: ...injury or damage Mind the weight of the appliance during transport Lift appliance by the carrying handle and carry it Pull out the transport handle until it audibly snaps into place Pull the appliance by its transport handle Prior to horizontal transport Remove the Plug n Clean detergent bottle from the intake and close it with the lid Secure the appliance against shifting and tipping over 몇 CAUTI...

Page 12: ... vice checked by the customer service Voltage reduction due to weak mains supply or when using an extension cable Upon switch on push the lever of the trigger gun first and then switch the power switch to I ON Check setting at the spray lance Check water supply for adequate delivery rate Pull out the sieve in the water connection using flat nose pliers and clean under running water Remove air from...

Page 13: ...pecifications Electrical connection Voltage 220 240 1 50 V Hz Connected load 2 8 kW Protection class IP X5 Protective class I Mains fuse slow blow 13 A Water connection Max feed pressure 0 6 MPa Max feed temperature 60 C Min feed volume 12 l min Max Suction height 0 5 m Performance data Working pressure 15 MPa Max permissible pressure 16 MPa Water flow rate 9 2 l min Max flow rate 10 l min Deterge...

Page 14: ...14 English Use only original KÄRCHER spare parts Spare Parts ...