background image

10 

English

Illustrations on Page 15

Mount loose parts delivered with appliance prior to start-
up.
You will need the 2 included screws as well as a Philips 
screwdriver PH 2.

Illustration 

Secure the wheels using the included plug. Align 
the plug properly!

Insert the cover and screw in.

Illustration 

Insert base.

Insert the included dowels all the way into the 
holes.

Secure the base with the enclosed screws.

Illustration 

Hook in storage for spray lance.

Secure the storage for the spray lance by means of 
two screws.

Illustration 

Attach the transport handle.

Secure the transport handle by means of two 
screws.

Illustration 

Hook the net into the hooks shown in the illustra-
tion.

Before 

initial

 startup, the high-pressure 

gun must be coupled to the high-pressure 
cleaner. 

Insert the mains plug into the socket. 

Within one minute, simultaneously 
press the + and - buttons on the high-
pressure gun.

Hold down the buttons until the entire 
signal strength symbol flashes.
Once coupling is complete, all six pressure levels 
will be displayed.

Note:

 You can find a detailed description of the coupling 

here: 

https//www.kaercher.com/FCR

Park the appliance on an even surface.

Illustration 

Completely wind off the high-pressure hose and 
disentangle any loops and knots.

Put the disentangled high-pressure hose through 
the hose guide from the back.

Illustration 

Push the high pressure hose into the trigger gun 
until it locks audibly.

Note:

 Make sure the connection nipple is aligned 

correctly.

Check the secure connection by pulling on the high 
pressure hose.

Insert the mains plug into the socket. 

For connection values, see type plate/technical data.

ATTENTION

Impurities in the water can damage the high-pressure 
pump and the accessories. For protection, the use of 
the KÄRCHER water filter (optional accessory, order 
no. 4.730-059) is recommended.

Observe regulations of water supplier.

ATTENTION

Hose couplings made of metal with aquastop can dam-
age the pump! Please use plastic couplings or KÄRCH-
ER brass couplings.

Illustration 

Screw the coupling element to the water connec-
tion on the appliance.

Attach the water supply hose to the coupling on the 
water connection.

Connect the water supply hose to the water supply.

Completely open the water tap.

This high-pressure cleaner is suited to work with the 
KÄRCHER suction hose with backflow valve (Optional 
accessory, order no. 2.643-100) to draw in surface wa-
ter, e.g. from water butts or ponds (see specifications for 
max. suction height). 

Note:

 With vacuuming operation, the coupling for the 

water connection is not required.

Fill the suction hose with water.

Screw the suction hose into the water connection of 
the appliance and insert it into the water source 
(e.g. rainwater drum).

Bleed the device as follows prior to operation:

Turn on the appliance “I/ON”.

Unlock the lever of the trigger gun.

Push the lever of the trigger gun, the device will 
switch on.

Using the +/- buttons, set the high-pressure gun to 
detergent level 1.

Let the device run (max. 2 minutes) until the water 
exits the trigger gun without bubbles.

Release the lever of the trigger gun.

Lock the lever of the trigger gun.

Assembly

Install wheels

Installing the base

Install storage for spray lance

Install the transport handle

Attach the net to the accessory compartment

Coupling of the high-pressure gun

Start up

Water supply

Water supply from mains

Drawing in water from open reservoirs

Summary of Contents for K 5 Full Control Plus

Page 1: ...K 5 Full Control Plus Operating Instructions Please read the operating instructions carefully before using the unit 59683470 12 17...

Page 2: ...roper use 9 Environmental protection 9 Assembly 10 Start up 10 Operation 11 Transport 12 Storage 12 Care and maintenance 12 Troubleshooting 13 Helpline 13 Accessories and Spare Parts 13 Warranty 14 Te...

Page 3: ...plug and the socket with wet hands Check the power cord with mains plug for damage prior to every use Immediately have damaged power cord replaced by an authorised customer service electrician Do not...

Page 4: ...um DANGER The user must use the appli ance as intended The person must consider the local condi tions and must pay attention to other persons in the vicinity when working with the appli ance Check imp...

Page 5: ...ity for the appli ance prior to any work on or with the appliance to prevent accidents or damage The water jet that is emitted from the high pressure nozzle results in a repulsion power acting on the...

Page 6: ...arator Ensure that the connection of your building water installation on which the high pressure cleaner is operated is equipped with a system separator pursuant to EN 12729 Type BA Water that has flo...

Page 7: ...cleaners aerosols can develop Inhaling aerosols can cause health damage Depending on the applica tion completely shielded noz zles e g surface cleaner that significantly reduce the emission of aqueous...

Page 8: ...8 English Description of the Appliance...

Page 9: ...achines vehicles buildings tools facades terraces gardening tools etc by means of a high pressure water jet if necessary with ad ditional cleaning agents with accessories replacement parts and cleanin...

Page 10: ...ction values see type plate technical data ATTENTION Impurities in the water can damage the high pressure pump and the accessories For protection the use of the K RCHER water filter optional accessory...

Page 11: ...n the system Optional accessories Most K RCHER detergents can be bought ready to use in a Plug n Clean detergent bottle DANGER When using detergents the material data safety sheet issued by the deterg...

Page 12: ...ge for the spray lance Coil the high pressure hose and hang it over the hose storage Store the mains connection in the accessory com partment Prior to extended storage periods as during the winter als...

Page 13: ...lug n Clean detergent bottle is placed into the detergent connection facing down Check replace the batteries Decrease the distance between high pressure gun and high pressure cleaner Couple it to the...

Page 14: ...240 1 50 V Hz Connected load 2 1 kW Type of protection IP X5 Protective class I Mains fuse slow blow 13 A Water connection Max feed pressure 0 8 MPa Max feed temperature 40 C Min feed volume 10 l min...

Page 15: ...English 15 Illustration...

Page 16: ...http www kaercher com dealersearch...

Reviews: