background image

English

7

14

Transport handle

15

Trigger "0/OFF" / "I/ON"

16

Type plate

17

Quick coupling for the high-pressure connection

18

Screws

19

*Garden hose (fabric reinforced, diameter at least 
1/2 inch (13 mm), length at least 7.5 m, with com-
mercially available quick coupling)

20

Water connection coupling

21

Sieve

22

Water connection

23

Suction hose for detergent

24

Detergent filter

* additionally required 

Safety devices

CAUTION

Missing or modified safety devices!

Safety devices are provided for your own protection.
Do not bypass, remove or render ineffective any safety 
devices.

Power switch

The power switch prevents unintentional operation of 
the device.

High-pressure gun lock

The lock locks the lever of the high-pressure gun and 
prevents the device from starting unintentionally.

Auto-stop function

If the lever of the high-pressure gun is released, the 
pressure switch turns off the pump and the high-pres-
sure jet stops. The pump switches on again when the le-
ver is pressed. 

Symbols on the device

Installation

For the illustrations, refer to the graphics page.

Fit the supplied loose parts onto the device before start-
ing up the device.
Place the screws provided and matching screwdriver at 
the ready.

Mounting the storage option for the high-

pressure gun

1. Attach the storage for the high-pressure gun to the 

device with the two screws.

Illustration B

Installing the water connection coupling

1. Screw the water connection coupling onto the water 

connection on the device.

Illustration C

Initial startup

1. Place the device on a flat and level surface.
2. Unwind the high-pressure hose and eliminate any 

loops and twists.

3. Connect the high-pressure hose to the device.

a Pull up the clamp on the coupling.
b Insert the high-pressure hose into the coupling.
c Press down the clamp on the coupling. 

Illustration D

4. Connect the high-pressure hose to the high-pres-

sure gun.
a Squeeze the clamp.
b Pull out the clamp.
c Insert the high-pressure hose.
d Press the clamp in until it latches into place.

Illustration E

5. Check for a secure connection by pulling on the 

high-pressure hose.

6. Plug the mains plug into a mains socket.

Water supply

For the connection values, see the type plate or chapter 

 

Technical data

.

Observe the water distribution company regulations.

ATTENTION

Damage through contaminated water

Contamination in the water can damage the pump and 
the accessories.
KÄRCHER recommends using the KÄRCHER water fil-
ter for protection(special accessory, order number 
4.730-059).

Connection to the water line

ATTENTION

Hose coupling with Aquastop on the water connec-
tion of the device

Damage to the pump
Never use a hose coupling with Aquastop on the water 
connection of the device.
You can use an Aquastop coupling on the tap.

1. Plug the garden hose onto the water connection

coupling.

2. Connect the garden hose to the water line.

Illustration F

3. Open the water tap fully.

Operation

ATTENTION

Pump running dry

Damage to the device
If pressure does not build up in the device after 2 min-
utes then switch the device off and proceed according 
to the instructions in chapter  Troubleshooting guide.

ATTENTION

Failure to adhere to the correct device position

Damage to the pump
Operate the device in a horizontal position only.

Do not aim the high-pressure jet may at per-
sons, animals, live electrical equipment or 
the device itself.
Protect the device against frost.
The device may not be connected to the 
public drinking water network.