background image

English  

5

Wear protective clothing and safety 
goggles to protect against splash back 
containing water or dirt.

Caution

In case of extended downtimes, switch 
the appliance off at the main switch / ap-
pliance switch or remove the mains 
plug.

Do not operate the appliance at temper-
atures below 0 °C.

Observe a distance of at least 30 cm 
when using the jet to clean painted sur-
faces to avoid damaging paintwork.

Never leave the appliance unattended 
when it is in operation.

Make sure that the power cable or ex-
tension cables are not damaged by run-
ning over, pinching, dragging or similar. 
Protect the power cable from heat, oil, 
and sharp edges.

All current-conducting parts in the work-
ing area must be protected against jet 
water.

The appliance may only be connected 
to an electrical supply which has been 
installed in accordance with IEC 60364.

The appliance may only be connected 
to alternating current. The voltage must 
correspond with the type plate on the 
appliance.

For safety reasons, we recommend that 
you operate the appliance only via a 
earth-leakage circuit breaker (max. 
30 mA).

Cleaning operations which produce oily 
waste water, e.g. engine washes, un-
derbody washes, may only be carried 
out using washing stations equipped 
with an oil separator.

The high pressure hose is specially con-
structed with reinforced walls to handle wa-
ter pressure up to 11 MPa (1600 psi) - it can 
be easily damaged and should be stored 
carefully.

Do not kink.

Do not drive vehicles over the hose.

Do not expose the hose to sharp edges 
or corners.

Misuse will lead to ballooning or premature 
failure and will invalidate warranty.

Caution

Safety devices protect the user and must 
not be modified or bypassed.

The appliance switch prevents unintention-
al operation of the appliance.

This lock locks the lever of the trigger gun 
and prevents the inadvertent start of the ap-
pliance.

If the lever on the trigger gun is released 
the pressure switch turns off the pump, the 
high-pressure jet is stopped. If the lever is 
pulled the pump is turned on again.

Caution

Create stability for the appliance prior to all 
work on or with the appliance to prevent ac-
cidents or damage.

The stability of the appliance is warrant-
ed when it is placed onto an even sur-
face.

High pressure hose

Safety Devices

Power switch

Lock trigger gun

Overflow valve with pressure switch

Prerequisites for the appliance's 

stability

Summary of Contents for K 256 M

Page 1: ...Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them 59635630 03 11 K 256 M...

Page 2: ...be recycled Please arrange for the proper recycling of old appliances Please dispose your old appliances using appropriate collec tion systems Notes about the ingredients REACH You will find current...

Page 3: ...le transport handle 8 Storage for spray lance 9 Storage for trigger gun 10 Mains cable with mains plug 11 Water connection 12 Bearing wheel 13 Coupling element for water connection 14 Trigger gun 15 L...

Page 4: ...lvents or undiluted acids and solvents This in cludes petrol paint thinner and heating oil The spray mist thus generated is highly inflammable explosive and poi sonous Do not use acetone undiluted aci...

Page 5: ...ing operations which produce oily waste water e g engine washes un derbody washes may only be carried out using washing stations equipped with an oil separator The high pressure hose is specially con...

Page 6: ...o the coupling unit then connect it to the wa ter supply Caution Dry runs lasting longer than two minutes lead to damages to the high pressure pump If the appliance does not build up pressure within t...

Page 7: ...igh pressure hose from the trigger gun or the appliance while there is no pressure in the system After working with detergent suspend detergent suction hose in a container filled with clear water swit...

Page 8: ...er from the ap pliance Switch the appliance on with detached high pressure hose and de tached water supply max 1 minute and wait until no more water exits at the high pressure connection Turn off the...

Page 9: ...e and rinse through with wa ter from the front Check water flow quantity Slight leakage from the appliance pump is normal If the leakage increases con tact the authorized customer service Detach spray...

Page 10: ...n class IP X5 Water connection Max feed pressure 1 2 MPa Max feed temperature 40 C Min feed volume 8 I min Performance data Working pressure 9 MPa Max permissible pressure 11 MPa Water flow rate 6 0 I...

Page 11: ...English 11 Spare Parts...

Page 12: ......

Reviews: