9. TECHNICAL DATA
Power Connection
Voltage
................. 230-240
V -AC
Current
...................... 1~50
Hz
Connected/Load
.......................... 1.2
KW
Mains Fuse
........................... 13
AMP
Water Connection
Supply Temperature (Max)
........................... 40
°C
Supply Rate (Min)
.............................8
litres per minute
Supply Pressure (Max)
(12 bar) ...............
1,2
MPa
Supply Hose: Length
.......................... 7.5
metres
Diameter
.......................... 1/2
inch
Performance Data
Pump Pressure (Max)
(100 bar) ............. 10
MPa
Operating Pressure
(85 bar) .............. 8.5
MPa
Flow Rate
(300 L/h) ...............5
litres per minute
Detergent Intake
.......................... 0,3
litres per minute
Recoil Force of Hand Held Spray Gun at Operating
Pressure (Max)
........................... 15
N
Unit vibrations
.......................... 0.8
m/s²
Noise level L
PA
(EN 60704-1)
........................ 74,5
dB (A)
Noise level L
WA
(
2000/14/EEC
)
........................... 87
dB(A)
Optimum Working Distance on High Pressure .... 30
cm
Dimensions: K 209 (K 209 M)
Length/Width/Height .... 390/205/300 (555/260/315)
mm
Weight ...................................................... 10 (10,5)
kg