English
19
Screw the suction hose into the water
connection of the appliance and insert it
into the water source (e.g. rainwater
drum).
Separate the high pressure hose from
the high pressure connection of the ap-
pliance.
Switch the appliance on (I/ON) for a
max. of 2 minutes and wait until the wa-
ter exits the high-pressure connection
without bubbles.
Turn off the appliance "0/OFF".
Turn on the appliance “I/ON”.
The displays for battery operation and
mains operation are subjected to a brief
test routine and will illuminate consecu-
tively.
The display for battery operation illumi-
nates continuously and shows the bat-
tery status.
The appliance is now ready for opera-
tion.
– Battery empty: Motor will be switched
off, the three red LEDs will blink and
thhen shine ca. 60 seconds - then the
appliance will shut off on its own.
– Engine or battery pack is too hot: the
appliance will shut off on its own.
Connect charging station with power
cord and plug into the mains socket.
Insert the battery pack into the charger.
ATTENTION
Dry running of more than 2 minutes leads to
damage of the high-pressure pump. If the
appliance does not build up pressure within
2 minutes, switch the appliance off and pro-
ceed in accordance with the instructions in
Chapter "Troubleshooting".
Pressing the „ON-/OFF“-switch starts
the appliance in maximum mode.
Pressing the „ON-/OFF“-switch again
switches to the ECO-mode.
Pressing the „ON-/OFF“-switch again
switches the appliance off.
몇
CAUTION
Keep a distance of at least 30 cm when us-
ing the jet for cleaning painted surfaces to
avoid damage.
Illustration
Push the spray lance into the trigger gun
and fasten it by turning it through 90°.
Turn on the appliance “I/ON”.
Unlock the lever on the trigger gun.
Pull on the lever of the trigger gun; the
device will switch on.
Note:
Release the lever of the trigger
gun; the device will switch off again.
High pressure remains in the system.
Drawing in water from open reservoirs
Battery operation
Display battery oper-
ation
Charging status
of the battery
pack
green LED red LED
3
0
70% - 100%
2
0
40% - 70%
1
0
20% - 40%
0
3 blinking 10% - 20%
0
3
1% - 10%
Charging the battery
LED 1 LED 2
No battery pack in the
charger
OFF
OFF
Low voltage protection OFF
Blinking
Charging process
Blinking OFF
Charging process com-
pleted
ON
OFF
Temperature too high
OFF
ON
Short-circuit
OFF
ON
Operation
Operating modes
High pressure operation
Summary of Contents for K 1 Battery Lite
Page 1: ...5 English 12 97625940 06 17 K 1 Battery K 1 Battery Lite...
Page 2: ......
Page 3: ...3 A B...
Page 4: ...4...
Page 5: ...5 K RCHER REACH www kaercher com REACH 5 5 5 5 5 8 8 8 9 10 10 10 10 11 11 11...
Page 6: ...6 30 cm 0 C 24...
Page 7: ...7 EN 12729 BA FFP 2...
Page 10: ...10 1 K RCHER 2...
Page 12: ...12...