76
English
5.906-432.0 Rev. 00 (06/15)
7.5
Set up the switching off process
Function
Adjustments
LED indicator
Important
30 °C
(30/30 °C)
ON30MIN
Behaviour of device after
30 minutes of continuous
operation.
The setting will be saved.
The device switches off after 30 minutes of
continuous operation.
The device does not switch off after 30 min-
utes of continuous operation (factory set-
ting).
35 °C
(34/32 °C)
OFF30MIN
Behaviour of device after
30 minutes of continuous
standby operation.
The setting will be saved.
The device switches off after 30 minutes in
the standby mode.
The device does not switch off after 30 min-
utes in the standby mode (factory setting).
7.6
Set up the leakage behaviour
Function
Adjustments
LED indicator
Important
40 °C
(37/34 °C)
LECKAGEONOFF
Behaviour of the device
after 10 short startups of
the pump (run time of the
pump under 2 seconds).
The setting will be saved.
Device switches off after 10 short startups
of the pump (factory setting).
The device does not switch off after 10
short startups of the pump.
Summary of Contents for HDS 7/12 M
Page 14: ...14 English 5 906 432 0 Rev 00 06 15...
Page 60: ...60 English 5 906 432 0 Rev 00 06 15 6 29 Functional diagram vacuuming operation...
Page 125: ...English 5 906 432 0 Rev 00 06 15 125 Circuit diagram 0 089 021 0 HDS 7 12...
Page 126: ...126 English 5 906 432 0 Rev 00 06 15 Circuit diagram 0 089 025 0 HDS 8 18 HDS 9 18...
Page 128: ...128 English 5 906 432 0 Rev 00 06 15 Circuit diagram 0 088 952 0 HDS 10 20 HDS 12 18...
Page 130: ...130 English 5 906 432 0 Rev 00 06 15 Circuit diagram 0 089 9026 0 HDS 13 20...