– 2
Illustration
1 High pressure hose
2 Cable clamp
3 Pouring vent for fuel
4 Filling level display
5 Storage compartment for nozzles
6 Power supply
7 High-pressure pump
8 Water supply set
9 High pressure connection (HDS 5/xx U
only)
10 Storage for spray pipe
11 Water connection with filter
12 Power switch
13 Cover
14 Carrying handle
15 Output opening of the high pressure
hose (HDS 5/xx U only)
16 Support
17 Wheel
18 Burner
19 Hose storage (HDS 5/xx U only)
20 Hose drum (HDS 5/xx UX only)
21 Detergent suction hose with filter
22 Support for spray lance
23 Nameplate
24 Cover lock
25 Hand crank for hose drum (HDS 5/xx
UX only)
26 Push handle
27 Marking of the nozzle
28 Triple nozzle
29 Spray lance
30 Safety latch of the hand spray gun
31 Lever for trigger gun
32 Hand spray gun
– The operating elements for the cleaning
process are yellow.
– The controls for the maintenance and
service are light gray.
High-pressure jets can be dan-
gerous if improperly used. The
jet may not be directed at per-
sons, animals, live electrical
equipment or at the appliance
itself. The high pressure cleaner must only
be used while standing.
– Cleaning of: Machines, Vehicles, Struc-
tures, Tools, Facades, Terraces, Gar-
dening tools, etc.
– The high pressure cleaner must only be
used while standing.
– Never leave the appliance unattended
as long as it is in operation.
DANGER
Risk of injury! Follow the respective safety
regulations upon employment at gas sta-
tions or other dangerous areas.
Quality requirements for water:
ATTENTION
Only clean water may be used as high
pressure medium. Impurities will lead to in-
creased wear and tear or formation of de-
posits in the appliance.
If recycled water is used, the following limit
values must not be exceeded.
Device elements
Colour coding
Symbols on the machine
Device with hose drum:
Risk of burns on account of hot
surfaces!
Proper use
Please do not let mineral oil contaminated
waste water reach soil, water or the sew-
age system. Perform engine cleaning and
bottom cleaning therefore only on speci-
fied places with an oil trap.
pH value
6,5...9,5
electrical conductivity *
Conductivity
fresh water
+1200
μ
S/cm
settleable solids **
< 0,5 mg/l
total suspended solids *** < 50 mg/l
5
EN