background image

• 9.801-810.0 • Operator's Manual • Rev. B

OPERA

TOR’S MANUAL

    

PRESSURE 

W

ASHER  

6

COMPONENT IDENTIFICATION

Pump 

— Develops high pressure.

Spray Gun

 — Controls the application of water and 

detergent onto cleaning surface with trigger device. 

Includes safety latch.

Wand

 — Must be connected to the spray gun.

Unloader

 — Safety device that relieves pressure when 

spray gun trigger is closed.

High Pressure Hose

 — Connect one end to water 

pump discharge nipple and the other end to spray gun.

Pump Protector 

— Cycles fresh cool water through 

pump when recirculating water reaches 140°F.

GFCI

  —  Ground  fault  circuit  interrupter  trips  when 

voltage leaks to ground.

Note

:

 If trigger on spray gun is released for more 

than 1-2 minutes, water will leak from valve. Warm 

water will discharge from pump protector onto 

floor. This system prevents internal pump damage.

Spray Gun 

and Wand

High Pressure 

Hose

Pump

Pressure 

Nozzle

Garden Hose 

(not included)

Unloader

Detergent 

Bucket (not 

included)

Water Supply

(not included)

Handle

Quick 

Coupler

On/Off

Switch

GFCI

Pump 

Protector

Safety 

Latch

Summary of Contents for HD 2.0/1000 Ed

Page 1: ...0 OPERATOR S MANUAL MODEL ORDER HD 2 0 1000 Ed 1 106 124 0 HD 1 9 1300 Ed 1 106 125 0 HD 3 0 1000 Ed 1 106 126 0 HD 3 5 2000 Ea HD 1 8 1300 Ed 1 106 127 0 1 106 128 0 KNA Inc 4555 Airport Way Denver...

Page 2: ......

Page 3: ...You should record both serial number and date of purchase and keep in a safe place for future reference 9 801 810 0 Operator s Manual Rev B Important Safety Information 4 5 Component Identification 6...

Page 4: ...ician plumber utility company or the selling distributor for specific details If your machine is rated 250 volts or less single phase will be provided with a ground fault circuit interrupter GFCI If r...

Page 5: ...ZING WARNING Protect machine from freezing 13 To keep machine in best operating conditions it is important you protect machine fromfreezing Failuretoprotect machine from freezing could cause malfuncti...

Page 6: ...charge nipple and the other end to spray gun Pump Protector Cycles fresh cool water through pump when recirculating water reaches 140 F GFCI Ground fault circuit interrupter trips when voltage leaks t...

Page 7: ...y gun using teflon tape on wand threads STEP 3 Pull spring loaded collar of the wand coupler back to insert your choice of pressure nozzle STEP 6 Connect garden hose to the cold water source ASSEMBLY...

Page 8: ...ut engaging the safety latch on the spray gun trigger Safety Latch STEP 3 Connect to appropriate power supply Push reset button on GFCI STEP 4 Turn machine on by turning switch at top of motor On Off...

Page 9: ...ING TIPS Pre rinse cleaning surface with fresh water Place de tergent suction tube directly into cleaning solution and apply to surface at low pressure for best results limit your work area to section...

Page 10: ...pressure Pump Water Inlet High Pressure Outlet Safety Latch STORAGE CAUTION Pump Storage CAUTION Always store your pres sure washer in a location where the temperature will not fall below 32 F 0 C Th...

Page 11: ...nd replace if necessary Foreign matter in valves Check and clean if necessary Worn bearings Check and replace if necessary Excessive temperature of water Reduce to below 160o F PRESENCE OF WATER IN PU...

Page 12: ...f your pressure washer Perform maintenance more often under severe conditions OIL CHANGE RECORD Check pump oil and engine oil level before first use of your new pressure washer Date Oil Changed Month...

Page 13: ...25 Yellow 1 8 712 339 0 Nozzle SAQCMEG 2503 25 Green 1 8 712 340 0 Nozzle SAQCMEG 4003 25 White 1 8 712 398 0 Nozzle Compl Qcem 6540 Brass chem 1 Quick Connect Nozzle Kit 5 5 HD 3 0 1000 Ed 8 712 358...

Page 14: ...MBLY PARTS LIST ITEM PART NO DESCRIPTION QTY 5 9 802 166 0 Coupler 3 8 Female Brass 1 6 9 802 170 0 Coupler 3 8 PLUG FEMALE STEEL ZINC 1 7 9 802 216 0 Injector Chem 0 083 1 8 6 388 216 0 Hose DN 5 1 9...

Page 15: ...MANUAL Date Oil Changed Month Day Year Estimated Operating Hours Since Last Oil Change Date Oil Changed Month Day Year Estimated Operating Hours Since Last Oil Change OIL CHANGE RECORD Check pump oil...

Page 16: ...KNA Inc 4555 Airport Way Denver CO 80239 Form 9 801 810 0 Rev B Printed in U S A or Mexico...

Reviews: