background image

Page 9/11

International Service Information

International Service Information

Dec. 22nd,1999

HD 1050 DE Cage

New Unit Information

-   Mount shut-off valve with testing pressure

gauge on high-pressure outlet (see page 8

step 1, 2), set servopress handgun to max.

water volume, set three-way nozzle to 0° pencil

jet and operate the unit.

- Measure operating pressure and flow rate

(see technical data).

- Adjust engine r.p.m. with adjusting screw (3)

so that max. operating pressure (see

technical data) at testing pressure gauge is

achieved. With this operating pressure the

corresponding operating speed must also be

achieved (see technical data).

- Close and open servopress handgun several

times and check the adjustment. When the

handgun is closed, the pump pressure

decreases (circulation operation) and the

engine r.p.m. reduces.

- Finally seal screws (3), (5) and (13) with safety

paint.

1 Operating speed control

2 Locking nut

3 Adjusting screw

4 Locking nut

5 Adjusting screw

6 Bowden cable

7 Adjusting screw for max. operating speed

8 Locking nut

9 Engine stop lever

10 Regulator lever

11 Spring

12 Spring

13 Clamping screw

14 Spring

Note

:

Before adjusting the operating speed, the

overflow valve must be adjusted correctly. The

operating speed can only be adjusted during

high pressure (max. operating pressure / flow

rate).

Basic setting: operating speed

Summary of Contents for HD 1050 DE Cage

Page 1: ...Page 1 11 InternationalServiceInformation International Service Information Dec 22nd 1999 HD 1050 DE Cage New Unit Information HD 1050 DE Cage 1 810 993 5 905 870...

Page 2: ...low control 3 Servopress handgun 4 Spray lance 5 Three way nozzle 6 Yanmar diesel engine 7 Throttle lever engine stop 8 Oil dipstick 9 Recoil hand starter 10 Fuel tank 11 Battery 12 Pressure gauge 13...

Page 3: ...ode High pressure pump Similar to HD 895 S 3 piston axial pump Piston made of stainless steel diameter 16 mm High pressure seals low pressure seals oil seals Cylinder head made of brass Suction and pr...

Page 4: ...ew Unit Information Technical features high pressure pump 1 Pressure gauge 2 Non returnvalve 3 Pressurevalve 4 Oilreservoir 5 Shaftseal 6 Swash plate bearing 7 Swashplate 8 Axial roller bearing 9 Oil...

Page 5: ...or 3 Cleaningagentconnection 4 Controlpressureinjector 5 Pressure gauge 6 Non returnvalvescrewplug 7 Pressurechamber 8 Connection bore from pressure chamber to ball 9 9 Ball 10 Spring 11 Suctionchambe...

Page 6: ...the ball 9 off its seat so that part of the water can flow through the connection bores 8 and 12 to the suction chamber 11 3 Servopress handgun is completely closed When the handgun is completely clos...

Page 7: ...en cable Note The governor springs 3 and 4 must be attached in the holes of the governor levers 5 and 6 1 Adjusting screw 2 Spring 3 Clamping screw 4 Governor spring 5 Governor spring 6 Governor lever...

Page 8: ...tervolume open it and operate the unit Closeshut offvalve 1 slowlyuntillowpressure flow rate has been achieved see technical data This corresponds to the smallest servopress setting Measure flow rate...

Page 9: ...sponding operating speed must also be achieved see technical data Close and open servopress handgun several timesandchecktheadjustment Whenthe handgun is closed the pump pressure decreases circulation...

Page 10: ...high pressure nozzle Check clean water inlet filter Check adjust engine r p m Eliminate leakages in high pressure system as mentioned above Check adjust spring at overflow valve Replace suction and pr...

Page 11: ...m Fastening screw for pressure valve 40 45 Nm Injector 1 5 2 5 Nm Valve seat for safety valve 8 10 Nm The technical data sheet and circuit diagram are on the next edition of the Spare Parts CD ROM DIS...

Reviews: