– 7
몇
DANGER
–
Danger of injury by electric shock.
–
The appliance should always be
connected to the electrical mains
using a plug. It is forbidden to per-
manently connect the appliance to
the power supply. The plug is only
for mains separation.
–
The plug and coupling of the exten-
sion cable used must be watertight.
–
Use the extension cord that has an
adequate cross-section (see "Tech-
nical Data") and unwind it fully from
the cable drum.
For connection values, see type plate/
technical data.
Unwind the mains cable and place it
on the floor.
Insert the mains plug into a socket.
Observe regulations of water supplier.
For connection values refer to techni-
cal specifications.
Connect the supply hose (min.
length 7.5 m, minimum diameter 1/
2“) to the water connection point of
the machine and at the water sup-
ply point (for e.g. a tap).
Note
The supply hose is not included.
Open the water supply.
Screw the suction hose with filter
(optional accessory) to the water
connection.
Appliance ventilation:
Unscrew the nozzle from the spray
lance.
Switch on the appliance and let it
run until the water exiting is bubble-
free.
Let the appliance run for 10 sec-
onds – then switch off the appliance
switch. Repeat the procedure sev-
eral times.
Switch off the appliance and fit the
nozzle again.
STEP 1:
Plug the Ground Fault Cir-
cuit Interrupter (GFCI) into a work-
ing outlet.
STEP 2:
Press ’’TEST’’, then press
’’RESET’’ to assure proper connec-
tion to power.
Note: The actual appearance of the
GFCI may be different from this il-
lustration.
DANGER
Risk of explosion!
Do not spray flammable liquids.
If the appliance is used in hazardous
areas (e.g. filling stations) all of the
safety provisions and operating in-
structions detailed in this manual must
be observed.
Risk of injury! Hold the hand spray gun
and the spray pipe firmly with both
hands.
Electrical connection
Water connection
Connection to the water supply
Drawing in water from open reser-
voirs
HD 1.8/13 only: GFCI IN-
STRUCTIONS
Operation
10
EN
Summary of Contents for HD 1.8/13 C Ed Series
Page 1: ...HD 1 8 13 C Ed HD 4 9 C 59668980 11 23 English 4 Fran ais 17 Espa ol 32...
Page 2: ...2...
Page 3: ...3...
Page 47: ......