12

English

Install a pressure equalization container if the leaks 
cannot be eliminated (see chapter  Accessories and 
spare parts).

The pump stops in Automatic mode, the "Pressure 
side error" LED lights up

The pump switches frequently on and off due to leaks.
1. Check the pressure side for leaks (e.g. dripping wa-

ter tap).
Install a pressure equalization container if the leaks 
cannot be eliminated (see chapter  Accessories and 
spare parts).

2. Switch on the pump.
The pressure is too low after switching off the pump. 
The device starts again immediately and switches fre-
quently on and off.
1. Increase the pressure at the pressure side.

For garden applications, use a garden hose with 
minimum length of 5 m when the diameter is ¾" 
or 15 m when the diameter is ½".

With a permanent installation, install a pressure 
equalization hose or pressure equalization con-
tainer (see chapter  Accessories and spare 
parts).

2. Switch on the pump.

The pump stops in Manual mode, the "Pressure 
side error" LED lights up

The pump runs for at least 4 minutes, although the pres-
sure side outlet (e.g. water tap) is closed. The overheat 
protection switches off the device. 
1. Pull the mains plug out of the socket.

2. Open the water dispenser connected to the pres-

sure side.
The device is depressurised.

3. Switch on the pump.

The pump capacity drops or is too low.

Dirt particles block the suction area.
1. Pull the mains plug out of the socket.
2. Clean the suction area.
The pre-filter is soiled.
1. Pull the mains plug out of the socket.
2. Allow the pump to cool down.
3. Clean the suction area.
4. Clean the pre-filter (see chapter  Cleaning the pre-

filter).

5. Flush dirt residues at the base of the filling nozzle 

out through the filling hole.

6. Switch on the pump.
The suction side is leaking.
1. Check the suction side for leaks.
The maximum lifting height is exceeded or the flow rate 
is not optimised.
1. Observe the maximum lifting height (see chapter  

Technical data).

2. If necessary, select a different hose diameter or a 

different hose length (see chapter  Optimising the 
flow rate).

The pressure side outlet is restricted.
1. Fully open the valve or ball tap.
The pressure side hose is kinked.
1. Eliminate the kink points in the hose.

Technical data

Subject to technical modifications.

 

BP 3 Home 
& Garden

BP 4 Home 
& Garden

BP 5 Home 
& Garden

BP 7 Home 
& Garden

Electrical connection

Mains voltage

V

230-240

230-240

230-240

230-240

Power frequency

Hz

50

50

50

50

Nominal power

W

800

950

1000

1200

Device performance data

Maximum flow rate

l/h

3300

3800

6000

6000

Suction height (max.)

m

8

8

8

8

Pressure (max.)

MPa (bar) 0,40 (4,0)

0,45 (4,5)

0,48 (4,8)

0,60 (6,0)

Delivery height (max.)

m

40

45

48

60

Switch-on pressure in automatic mode (max.)

MPa (bar) 0,13 (1,3)

0,13 (1,3)

0,13 (1,3)

0,13 (1,3)

Particle size (max.) of permissible feed fluids

mm

1

1

1

1

Pump type

Jet

Jet

Multistage 
4-stage

Multistage 
5-stage

LED type to EN 60825-1

Class 1

Class 1

Class 1

Class 1

Application instructions

Watering (max.)

m

2

500

800

1000

1200

House supply (max.)

Persons

8

10

12

12

Wa house supply with 4 persons (max.)

m

2

300

600

800

900

Dimensions and weights

Weight (without accessories)

kg

10,3

10,6

12,5

13,0

Determined values to EN ISO 20361

Sound level L

pA

dB(A)

61

63

61

61

dB(A)

76

78

77

76