Check the mains cable regularly for
damage such as aging or formation of
cracks. If you find a damage, then the
cable must be replaced before using it
any further.
Î
Check appliance for damage, have
damages repaired by customer service.
–
For connection values, see technical
data and type plate.
–
The electrical connections must be
done by an electrician according to IEC
60364-1.
m
Danger
Risk of electric shock.
–
Do not drive over the mains cable.
m
Danger
Risk of injury.
–
Never wrap the mains cable around
your body or your neck.
–
Do not let the mains cable come in con-
tact with the rotating brushes or rotating
pads.
Caution
The highest allowed net impedance at the
electrical connection point (refer to techni-
cal data) is not to be exceeded. In case of
confusion regarding the power impedance
present on your connection, please contact
your utilities provider.
Î
Disconnect the mains plug from the
socket.
Î
Pull the lever for level adjustment and
bring the handle toward the front into a
vertical position.
Î
Tilt the appliance rearward.
Î
Place the disc brush/driver plate onto
the actuator and turn in anti-clockwise
direction.
1
Upper holder
2
Lower holder
Î
Undo the star handle screws on the top and
bottom supports.
Î
Hang the detergent tank (option) into the
lower support.
Î
Align and affix the detergent tank (option)
by sliding the two supports.
Î
Screw the star handle screws onto the sup-
ports.
Start up
Power connection
Attach the brush/pad
Install the detergent tank (option)