– 4
Î
Set handle to working height.
Î
Hold the handle with both hands.
Î
Press and hold the unlocking button.
Î
Activate the switch.
Î
Release the unlocking button.
Î
Release the switch to interrupt operation.
–
Left:
Press the handle downward.
–
Right:
Raise the handle.
Î
Apply the detergent solution to the floor
or use the dosing lever (accessory).
Î
Move the appliance over the surface to
be cleaned.
Î
Afterwards, pick up the wastewater with
a wet vacuum or a cloth.
Î
Release the switch.
Î
Disconnect the mains plug from the
socket.
Î
Pull the lever for level adjustment and
bring the handle in a vertical position.
Î
Swivel the top cable hook upward and
wind the cable between the two cable
hooks.
Î
Remove the detergent tank (accessory)
and dispose of unused detergent solu-
tion.
Î
Rinse the detergent tank (accessory)
with clear water.
Î
Pull the lever for level adjustment and
bring the handle toward the front into a
vertical position.
Î
Place the appliance into the parking po-
sition.
Î
Clean the casing with a damp cloth.
Caution
Risk of injury and damage! Observe the
weight of the appliance when you transport it.
Î
Swivel the handle vertically and lock it.
Î
Tilt the appliance backwards into the
transport position and drive it to its des-
tination location.
Caution
Risk of damage! Only transport the appli-
ance on the wheels; the small rollers on the
bottom of the cleaning head are not suita-
ble to be used for transport.
Î
When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.
Caution
Risk of injury and damage! Note the weight
of the appliance in case of storage.
Î
Pull the lever for level adjustment and
bring the handle toward the front into a
vertical position.
Î
Place the appliance into the parking po-
sition.
Î
Store the appliance in a dry room, frost-
protected room.
m
Danger
Risk of injury. Pull the plug from the mains be-
fore carrying out any tasks on the appliance.
In case of faults that cannot be remedied
using the table below please contact the
customer service.
Control the direction
Cleaning
Shutting down
Transport
Storage
Troubleshooting
Fault
Remedy
Insufficient
cleaning result
Replace contaminated
pads and wash them at
a max. temperature of
60 °C.
Replace worn disc
brush / pad.
Check the suitability of
brush/pad and deter-
gent for the respective
use.
Appliance vi-
brates strongly
Check for correct seat-
ing of disc brush/pad.
Check pad attachment.
Pad does not
turn
Check if foreign bodies
are blocking the brush/
pad; remove the foreign
bodies if required.
(1