![Kärcher 500 PSI-13 Gallon Manual Download Page 14](http://html1.mh-extra.com/html/karcher/500-psi-13-gallon/500-psi-13-gallon_manual_3946832014.webp)
14
86343340 PUZZI 50/35
Maintenance
Periodic Maintenance
Twice a month, flush a white vinegar solution (one
quart vinegar to two gallons of water) or anti-browning
solution (mixed as directed) through the machine. This
will prevent build-up of alkaline residue in the system.
Periodically inspect all hoses, electrical cables and
connections on your machine. Frayed or cracked hoses
should be repaired or replaced to eliminate vacuum or
solution pressure loss. The electrical cable must be
well insulated and cable connector screw kept tight. If
the cable insulation is broken or frayed, repair or
replace immediately. Don't take chances with electrical
fire or shock.
SERVICE SCHEDULE
DAILY WEEKLY QUARTERLY
Check machine for cord damage
*
Check recovery dome and gasket for damage and cleanliness
*
Check hoses for wear, blockages, or damage
*
Check handles, switches, and knobs for damage
*
Run one gallon of water through solution system
*
Clean out recovery tank and check float valve to make sure it moves freely
*
Clean out solution tank and remove and clean vacuum intake screen
*
Clean outside of all tanks and check for damage
*
Run vac motor for at least one minute to allow motor to dry
*
Store with dome off tank to allow the tank to dry
*
Check all gaskets for wear and leakage
*
Check pump pressure; observe spray pattern and check with gauge if
necessary
*
Check and clean solution screen
*
Check cables for fraying
*
Check overall performance of machine
*
Check vac motor carbon brushes
*
Daily/Regular Maintenance
Before making any repairs or adjustments to the
machine, disconnect the power cord from the elec
-
trical source.
1. Empty unused cleaning solution from the solution
tank.
2. Inspect and clean filter screen in solution tank.
3. Flush pumping system with 1 to 2 gallons of clean
water.
4. After each use, rinse tank with fresh water. Periodi
-
cally inspect the recovery tank and decontaminate
if necessary, using a Hospital Grade Virucide or a
10-1 bleach to water solution. Waste water should
be disposed of properly.
Do not allow machine to freeze.
Summary of Contents for 500 PSI-13 Gallon
Page 19: ...86343340 PUZZI 50 35 PARTS...
Page 20: ...20 86343340 PUZZI 50 35 Control Panel 1 6 3 13 12 12 2 5 14 7 4 8 9 15 11 10...
Page 22: ...26 86343340 PUZZI 50 35 Electrical 16 6 15 14 13 10 3 1 12 9 17 5 7 11 2 4 8 3 18 19...
Page 24: ...24 86343340 PUZZI 50 35 Frame 1 2 3 4 5 6 7 8 9 10 11...
Page 26: ...26 86343340 PUZZI 50 35 Labels 2 1 3 4...
Page 30: ...30 86343340 PUZZI 50 35 Recovery 17 9 7 1 10 12 13 10 5 20 16 14 8 2 4 19 3 15 18 11 6 21...
Page 34: ...34 86343340 PUZZI 50 35 Vacuum 1 5 8 7 4 10 3 11 13 6 9 12 5 2...
Page 39: ...86343340 PUZZI 50 35 39 Serial Numbers REF NO MODEL SERIAL 1 1 006 672 0 10066720000026...