6

5.  General Information

Safety Equipment

Safety Valve/Overflow valve

The safety valve is also an overflow valve.
When the hand-held spray gun is closed, the valve
opens and water flows back to the suction side of
the pump.

Spare Parts

A selection of the most common spare parts num-
bers is listed at the end of these operating in-
structions.

Guarantee

The terms and conditions of guarantee issued
by a national Kärcher Company are valid in the
relevant country.

If the appliance malfunctions in any way, the fault
will be rectified free of charge within the period of
the guarantee provided the malfunction is due to
faulty material or a manufacturing error and all the
terms and conditions are met.

6.  Technical Data

Circuit Diagram

Power connection

Voltage ................................................................. 240 V
Type of current ................................................. 1~ 50 Hz
Connected load ................................................... 1,75 kW
Mains fuse (slow) .................................................. 10 A

Water connection

Supply temperature (max.) ................................... 40 °C
Supply rate (min.) ................................................ 600 l/h
Supply pressure (max.) ......................................... 12 bar
Supply hose

–  length (min.) ............................................ 7,5 m
–  diameter (min.) ........................................ 1/2 in

Suction height from open tank
at a water temperature of 20°C .............................. 1 m

Performance data

Rated pressure .................................................... 100 bar
Permissible pump pressure (max.) .................... 110 bar
Flow rate ............................................................... 400 l/h
Detergent intake .................................................... 30 l/h
Recoil force of hand-held spray gun
at operating pressure (max.) ................................ 16 N
Sound pressure level (DIN 45635) ...................... 78 dB (A)

Dimensions

Length ................................................................... 432 mm
Width .................................................................... 170 mm
Height ................................................................... 300 mm
Weight with accessories ......................................... 8 kg

M 1 Motor
S 1 Switch
X 1 Plug
Z 1 Suppressor

Summary of Contents for 411

Page 1: ...5 956 435 Ä 09919 06 96 ...

Page 2: ...Please read these operating instructions before starting and strictly observe the Safety Instructions for High Pressure Cleaners 3 6 7 5 4 2 1 A ...

Page 3: ...irectly to the appliance 2 Allow the pump to operate without the high pressure hose until water appears at the high pressure outlet without any more bubbles 3 Then re attach the high pressure hose Note Dirt in the feed water could lead to the ap pliance being damaged To avoid this risk we re commend fitting a filter A suitable filter with 3 4 connectionisavailableunderOrderNo 6 414 389 Detergent S...

Page 4: ...irtwiththehigh pressure spray The appliance should be rinsed clean after de tergent has been used To do this suspend the detergent suction hose in a container of clean water and run the pump for approx 1 minute Interrupting Operation In the event of extended work breaks more than 15 minutes switch off the pump to avoid damage due to water overheating Switching Off the Appliance Switch off the pump...

Page 5: ... with malfunctions yourself In all other cases or in the case of electrical faults please contact the authorized customer service Appliance does not Work Check the mains voltage Check the connector cable for damage Appliance does not reach Operational Pressure Adjust the double nozzle to high pressure or cle an same Bleed the air from the appliance Suction 2 Clean the strainer in the water connect...

Page 6: ...function is due to faulty material or a manufacturing error and all the terms and conditions are met 6 Technical Data Circuit Diagram Power connection Voltage 240 V Type of current 1 50 Hz Connected load 1 75 kW Mains fuse slow 10 A Water connection Supply temperature max 40 C Supply rate min 600 l h Supply pressure max 12 bar Supply hose length min 7 5 m diameter min 1 2 in Suction height from op...

Page 7: ...45 922 6 389 716 0 6 389 716 0 6 414 384 0 6 362 078 0 5 443 229 0 5 310 065 0 06 96 402 411 1 945 930 GB 6 389 555 0 2 880 296 0 6 362 422 0 6 903 276 0 2 883 111 0 4 760 277 0 4 760 241 0 1 945 922 1 945 928 6 362 422 0 4 775 184 0 6 647 643 0 1 945 922 6 647 615 0 1 945 926 1 945 930 6 647 616 0 1 945 928 ...

Reviews: