background image

9

l

Pull the lever on the handgun until the unit is
without pressure.

l

Press in the safety button to protect the unit
against inadvertent switching on.

Caution! Frost can destroy an incompletely
emptied unit. In the winter keep the unit in a
frost-free room.

l

Separate the spray lance from the handgun
and place it in its holder.

CARE AND MAINTENANCE

FINISHING OPERATIONS

TRANSPORTATION

l

Switch off the unit before transporting it.

l

To transport it over stairs or obstacles lift the
unit at the transportation handle.

l

To transport the unit over even surfaces draw
it by the drawing bar.

Cleaning

Before long periods of storage, e.g. in winter:

l

Pull the cleaning agent metering valve off
the cleaning agent suction hose and clean
it under running water.

l

Pull out the strainer in the water inlet with flat-
nose pliers and clean it under running water.

Maintenance

The unit is maintenance-free.

Summary of Contents for 397 M plus

Page 1: ...5 959 644 07 00 550 M plus...

Page 2: ...nce at all times IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS Follow the maintenance instructions specified in the manual This Product Is Provided With A Ground Fault Circuit Interrupter Buil...

Page 3: ...t interrupter GFCI built into the plug of the power supply cord This device provides additional protection from the risk of electric shock Should replacement of the plug or cord become necessary use o...

Page 4: ...unit as authorized Use this unit exclusively for non industrial purposes for cleaning machines vehicles buildings tools facades terraces garden implements etc with high pressure water jet if necessar...

Page 5: ...ise needed The unit can also be operated with rain water use a water filter Ease the burden on waste water Please use the cleaning agents sparingly Observe the dosage recommendations which are supplie...

Page 6: ...ting and hold the handgun and spray lance firmly If necessary wear protective clothing for protection against return spray Water supply The unit can either be supplied from the water main or from wate...

Page 7: ...on OPERATION Connect accessories Depending on the model the following accessories are either included in the scope of delivery or are obtainable from specialist dealers see also Special accessories l...

Page 8: ...irt with the high pressure jet l Master switch to 0 l Draw out power plug Wind the high pressure hose around the hose reel OPERATION FINISHING OPERATIONS Cleaning agents For trouble free operation and...

Page 9: ...NCE FINISHING OPERATIONS TRANSPORTATION l Switch off the unit before transporting it l To transport it over stairs or obstacles lift the unit at the transportation handle l To transport the unit over...

Page 10: ...out of the housing underside Pump leaking 3 drops per minute are acceptable For greater leakages contact the customer service Cleaning agent is not drawn in Spray lance set to Set spray lance to Clean...

Page 11: ...i Performance data Operating pressure max 1500 psi Flow volume 1 7 gpm Cleaning agent metering 0 25 l h Suction height from open container 20 C 1 m Recoil force of the handgun 22 N Sound level LPA EN6...

Page 12: ...12 ASSEMBLY...

Page 13: ...13 Changing the high pressure hose...

Page 14: ...14 NOTES...

Page 15: ...15 SPARE PARTS...

Page 16: ......