9
Safety
THIS PRODUCT IS FOR COMMERCIAL
USE ONLY.
Electrical
In the USA this machine operates on a standard 15
amp 120V, 60 hz, A.C. power circuit. The amp, hertz,
and voltage are listed on the data label found on each
machine. Using voltages above or below those
indicated on the data label will cause serious damage
to the motors.
Extension Cords
If an extension cord is used, the wire size must be at
least one size larger than the power cord on the
machine, and must be limited to 50 feet (15.5m) in
length.
Grounding Instructions
This appliance must be grounded. If it should
malfunction or break down, grounding provides a path
of least resistance for electric current to reduce the
risk of electric shock. This appliance is equipped with
a cord having an equipment-grounding conductor and
grounding plug. The plug must be inserted into an
appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordi-
nances.
120 Volt Models
This appliance is for use on a nominal 120-volt circuit,
and has a grounded plug that looks like the plug in
"Fig. A". A temporary adaptor that looks like the
adaptor in "Fig. C" may be used to connect this plug
to a 2-pole receptacle as shown in "Fig. B", if a
properly grounded outlet is not available. The
temporary adaptor should be used only until a
properly grounded outlet (Fig. A) can be installed by a
qualified electrician. The green colored rigid ear, lug,
or wire extending from the adaptor must be
connected to a permanent ground such as a properly
grounded outlet box cover. Whenever the adaptor is
used, it must be held in place by a metal screw.
Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check
with a qualified electrician or service person if you are
in doubt as to whether the outlet is properly grounded.
Do not modify the plug provided with the appliance - if
it will not fit the outlet, have a proper outlet installed by
a qualified electrician.
Le raccordement incorrect du conducteur de terre
d'équipement peut entraîner des risques d'électrocu-
tion. Vérifiez auprès d'un électricien qualifié ou d'un
responsable de l'entretien si vous avez quelque doute
que ce soit quant au raccordement à la terre de votre
prise murale. Ne modifiez pas la fiche fournie avec
l'appareil: si elle ne correspond pas à la prise murale,
faites installer une prise adéquate par un électricien
qualifié.
86348550 BRC 30/15 C
GROUNDING
PIN
GROUNDED
OUTLET
ADAPTER
METAL SCREW
TAB FOR
GROUNDING SCREW
GROUNDED
OUTLET BOX
(A)
(B)
(C)
Summary of Contents for 1.008-058.0
Page 24: ...24 Brush Deck 16 1 7 6 1 2 3 4 5 1 7 8 9 10 11 12 13 14 15 17 86348550 BRC 30 15 C...
Page 26: ...26 Control Panel 1 2 3 6 5 8 7 9 4 86348550 BRC 30 15 C...
Page 28: ...28 Decal 2 1 3 4 5 6 86348550 BRC 30 15 C...
Page 30: ...30 Frame Wheels 11 13 7 6 5 4 3 2 1 10 8 9 12 86348550 BRC 30 15 C...
Page 34: ...34 Solution 1 86348550 BRC 30 15 C...
Page 36: ...36 Solution 2 86348550 BRC 30 15 C...
Page 38: ...38 Tank Dome 86348550 BRC 30 15 C...
Page 40: ...40 Vacuum 3 4 2 3 5 8 6 1 7 GROUND WIRE 86348550 BRC 30 15 C...
Page 48: ...48 Serial Number REF NO MODEL SERIAL 1 86348550 BRC 30 15 C...
Page 49: ...49 Notes 86348550 BRC 30 15 C...