Prolaser Multi Beam GREEN
Orbital laser
Model No. 962G
165'/50m
Up to 60m/200'
4 AA
INCLUDED
User Manual
Page 1: ...Prolaser Multi Beam GREEN Orbital laser Model No 962G 165 50m Up to 60m 200 4 AA INCLUDED User Manual...
Page 2: ...odes that emits a horizontal circular line vertical line and two plumb dots The laser is innovatively designed for a very broad range of Professional and DIY jobs including Hanging cabinets and shelve...
Page 3: ...3 CONTENTS Features 4 Safety instructions 5 6 Battery installation Safety 7 8 Overview 9 Operating instructions 10 12 Maintenance 13 Field calibration test 14 23 Specifications 24 Warranty 25...
Page 4: ...indoor working range 30m 100 The max detectable range of the laser in pulse mode is 60m 200 For optimal vertical line viewing position the laser at least 2 meters from the wall Manual mode allows angu...
Page 5: ...te the laser level near children or let children operate the laser level Do not look into a laser beam using magnifying optical devices such as binoculars or a telescope since it will increase the lev...
Page 6: ...0 C or above 45 C 14 F to 113 F Do not operate the laser in explosive atmospheres such as flammable liquids gases or dust Sparks can cause ignition When not in use remove the battery engage the pendul...
Page 7: ...uses 4 standard AA batteries Installation 1 Press down the ledge of the battery cover 2 Insert 4 new AA batteries of the same brand according to the polarity diagram on the battery cover 3 Reclose th...
Page 8: ...Battery can deteriorate leak or explode and can cause injury or fire 1 Do not shorten the battery terminals 2 Do not dispose of battery into household waste 3 Do not dispose of battery in fire 4 Defec...
Page 9: ...Beam Selector Manual mode button b Beam Battery indicator c Pulse Mode button d Pulse Mode indicator 3 Horizontal laser beam window 4 Forward vertical laser beam window 5 Down plumb dot window 6 Batte...
Page 10: ...s a 360 horizontal beam vertical beam and 2 plumb dots The beam indicator b will turn on 3 Press the beam selector button a to choose the required laser beams by cycle All beams Horizontal beam only V...
Page 11: ...that the beam is not leveled The beam indicator b will turn on 3 To mark a slope tilt the laser to the desired angle 4 To choose a beam briefly press the beam selector button a it will change the beam...
Page 12: ...aser beams 1 The pulse mode can be activated both in Automatic and in Manual mode 2 Turn on the laser level to the required mode 3 Press the Pulse mode button c to activate it The Pulse mode indicator...
Page 13: ...e laser level with a clean soft cloth Do not use solvents Although the laser level is dust and dirt resistant to a certain degree don t store in dusty places as long term exposure may damage internal...
Page 14: ...cy of the plumb line 1 Checking the Height Accuracy of the Horizontal beam Up and down deviation 1 Set up the laser on a tripod or on a flat stable surface between two walls A and B approximately 5met...
Page 15: ...15...
Page 16: ...16 6 Move the laser level towards wall B and position it approximately 0 5 meter from wall B 7 Mark on wall B the center of the cross beams as b2 see figure 3...
Page 17: ...send the laser level to a qualified technician for repair 2 Checking the Level Accuracy of the Horizontal beam Side to side inclination 1 Set up the laser on a tripod or on a flat surface at a distanc...
Page 18: ...18 3 Mark point a1 on the wall in the middle of the horizontal line at the left side of the wall see figure 5...
Page 19: ...ction of the beams moves approximately 90 mark a point a2 on the wall near a1 in the middle of the horizontal beam see figure 6 5 The distance between a1 and a2 should be no more than 1 5 mm if otherw...
Page 20: ...behind the plumb line near the plumb cone see figure 7 3 Set up the laser on a tripod or on a flat surface in front of the wall at a distance of approximately 2 meter 6 5 feet 4 Unlock the pendulum a...
Page 21: ...on the wall in the middle of the vertical beam at the same height as a1 see figure 8 7 The distance between a1 and a2 should be no more than 1 5mm if otherwise send the laser level to a qualified tec...
Page 22: ...1 Place the laser level on the floor 2 Unlock the pendulum and press the beam selector button to project the plumb laser dots on the ceiling and on the floor 3 Mark the center of the upper plumb dot o...
Page 23: ...e center of the upper plumb dot on the ceiling as point a2 See Figure 10 7 The distance between points a1 and a2 marked on the ceiling is an indication of the actual deviation of the line between the...
Page 24: ...leveling Range 3 Laser line width 2 mm 0 5mm 5m 0 10 0 02 at 20 Wavelength 510 530nm Laser Class II Power supply 4 AA Alkaline batteries Battery life Up to 8 hours of continuous operation Operating t...
Page 25: ...with proof of purchase Model 962G The serial number sticker is positioned inside the battery compartment CE CONFORMITY CERTIFICATE This product meets the standards of the Electromagnetic Compatibilit...
Page 26: ...1 00 Rev 3 0 2020 Kapro Industries Ltd...