• Do not remove or deface warning labels on the laser level.
• Do not disassemble the laser level, laser radiation can  
  cause serious eye injury.
• Do not drop the laser.
• Do not use solvents to clean the laser.
• Do not use in temperatures below -10°C or above 45°C
  (14°F / 113°F)
• Do not operate the laser in explosive atmospheres such as   

  flammable liquids, gases or dust. Sparks from the tool can  

  cause ignition.
• When not in use, turn off the power, engage the pendulum  
  lock and place the laser in the carrying pouch.
• Make sure the pendulum lock mechanism is engaged 
  before transporting the laser.

     

NOTE

If the pendulum lock mechanism is not 
engaged before transportation,  internal 
mechanical damage may occur.

Summary of Contents for Prolaser Bambino GREEN

Page 1: ...Prolaser Bambino GREEN Model No 842G User Manual 2AA 15m 50 INCLUDED...

Page 2: ...laser level with one green diode The laser is innovatively designed for a very broad range of professional and DIY jobs including Aligning tiles marble cabinets borders moldings and trimmings Marking...

Page 3: ...3 CONTENTS Features 4 Safety instructions 5 6 Battery installation Safety 7 8 Overview 9 Operating instructions 10 11 Maintenance 12 Field calibration test 13 18 Specifications 19 Warranty 20 21...

Page 4: ...within its self leveling range Visual warning blinking when the laser is out of leveling range falls Manual mode allows angular layout marking Locking mechanism to protect the pendulum during transpor...

Page 5: ...the laser level Do not look into a laser beam using magnifying optical devices such as binoculars or a telescope as this will increase the level of eye injury WARNING This product contains lead in so...

Page 6: ...above 45 C 14 F 113 F Do not operate the laser in explosive atmospheres such as flammable liquids gases or dust Sparks from the tool can cause ignition When not in use turn off the power engage the pe...

Page 7: ...according to the polarity diagram on the inside of the battery compartment 3 Close the battery cover BATTERY INSTALLATION SAFETY NOTE If the laser level will not be used for a long period of time remo...

Page 8: ...ttery terminals 2 Do not charge Alkaline batteries 3 Do not mix old and new batteries 4 Do not through batteries into household waste 5 Do not dispose of the batteries in fire 6 Defective or dead batt...

Page 9: ...9 OVERVIEW 1 On Off Locking Switch 2 Laser output window 3 Manual Mode button 4 Operation LED indicator 5 Battery cover 6 Tripod mount...

Page 10: ...lat vibration free surface or on a tripod 2 Push the locking switch 1 to the position The laser level will generate the crossed horizontal and vertical lines and the green LED will light up 3 If the i...

Page 11: ...de long press the 3 button The laser will project blinking cross lines and the red LED will light up 2 Tilt the laser to the desired slope 3 To turn the manual mode off press the Manual mode button ag...

Page 12: ...laser level with a clean soft cloth Do not use solvents Although the laser level is dust and dirt resistant to a certain degree do not store in dusty places as long term exposure may damage internal m...

Page 13: ...cy of the vertical line Checking the Height Accuracy of the Horizontal Line Up and down deviation 1 Set up the laser on a tripod or on a flat surface between two walls A and B approximately 5 meters a...

Page 14: ...he cross lines as b1 on the wall see figure 2 6 Move the laser level towards wall B and position it approximately 0 5 meters from wall B 7 On wall B mark the center of the cross lines as b2 see figure...

Page 15: ...se send the laser level to a qualified technician for repair Checking the Level Accuracy of the Horizontal Line Side to side inclination 1 Set up the laser on a tripod or on a flat surface at a distan...

Page 16: ...t edge of the horizontal line see figure 5 4 Turn the laser level counterclockwise until the right edge of the horizontal line reaches near a1 mark a point a2 on the wall in the middle of the horizont...

Page 17: ...plumb line has settled mark point a1 on the wall behind the plumb line near the plumb cone see figure 7 3 Set up the laser on a tripod or on a flat surface in front of the wall at a distance of approx...

Page 18: ...ll in the middle of the vertical line at the same height as a1 see figure 8 7 The distance between a1 and a2 should be no more than 2mm otherwise send the laser level to a qualified technician for rep...

Page 19: ...r line width 2 5 mm 0 5mm 5m 0 13 0 02 at 20 Wavelength 520 10nm Laser Class II Power supply 2 AA batteries included Battery life 12 hours of continuous operation Operating temp 10 C 45 C 14 F 113 F S...

Page 20: ...point of sale alongside your proof of purchase 2 After a return authorization procedure is initiated the laser level will be sent to an authorized repair lab 3 Once completed the product will be retur...

Page 21: ...ished by the European Directive 2014 30 EU and the Low Voltage Directive LVD 2014 35 EU EC DECLARATION OF CONFORMITY We declare under our responsibility that the product 842G is in accordance with the...

Page 22: ...22 Rev 2 0 2023 Kapro Industries Ltd...