Common fault and eliminating methods

3.1

Don’t start up

Cause

 

analysis:

(1)

 

Three

 

dry

 

cells

 

working

 

voltage

 

is

 

lower

 

than

 

3

 

V

(2)The

 

power

 

plug

 

contact

 

with

 

the

 

motherboard

(3)

 

The

 

travel

 

switch

 

contact

 

undesirable

Troubleshooting:
(1) Replace the battery in time

(2)Open

 

the

 

shell,

 

reinstall

 

the

 

power

 

plug

(3) Open the shell to adjust the position of the switch chip

Note: keyboard or motherboard damage can also cause cannot boot (less likely), 

and to change the contact.

3.2

After startup without laser line

Cause

 

analysis:

(1)   Instrument   tilt   is   too   large,   beyond   the   scope   of   work   is   the   police
(2)

 

laser

 

tube

 

main

 

board

 

attachment

 

poor

 

contact

 

or

 

broken

Troubleshooting:
(1)Adjust   the   Angle   of   screw   adjust   equipment   to   work   within   the   scope   of   returned   to   normal
(2)

 

To

 

open

 

the

 

shell

 

welding

 

laser

 

tube

 

connection

Note: the main board or damage to the laser tube can also be caused no laser line (less likely), and to 

11

Summary of Contents for Prolaser 862

Page 1: ...862 Laser level Maintenance manual KAPRO 1...

Page 2: ...2 Battery cover assembly 5 2 3 Pendulum assembly 6 2 4 Lock seat assembly 7 2 5 Battery box assembly 8 2 6 Electrical jobs chart 8 3 Common fault and eliminating methods 9 3 1 Don t start up 9 3 2 Af...

Page 3: ...The instrument can produce two mutually orthogonal laser sector a horizontal and a vertical plane Laser sector projected on the walls laser line creating two orthogonal As shown in the figure below la...

Page 4: ...ly NO NAME Material QTY 1 862 Pendulum Assembly 1 2 862 1 4 base screw sus304 1 3 886 23 battery cover assembly 1 4 862 main board PCBA 1 5 GB_CROSS_SCREWS_TYPE1 M2 5X5 5 H type N 2 6 862 Switch butto...

Page 5: ...screw 2AL12 1 14 GB_FASTENER_WASHER_SMW C 2 5 SUS304 2 15 GB_CROSS_SCREWS_TYPE128 ST2 2X4 5 H C N SUS304 1 16 GB_CROSS_SCREWS_TYPE128 ST2 2X9 5 H C N SUS304 1 17 GB_CROSS_SCREWS_TYPE128 ST2 9X13 H C N...

Page 6: ...NO NAME Material QTY 1 935 Magnet MAGNET 2 2 862 rubber SI RUBBER 4 3 862 Battery cover PA6 30GF 1 2 3 Pendulum assembly 6...

Page 7: ...5 4 4 GB_FASTENER_SCREWS_HSFP M3X5 N 45 4 5 hex socket set screws with flat point gb M5 12 SUS304 4 6 872 deep groove ball bearings gb 4 7 872 1 center shaft 1 SUS304 1 8 872 pressure ring HPb59 1 4 9...

Page 8: ...5 o rings series a GB Rubber 1 16 875 On line plate 1 17 GB_CROSS_SCREWS_TYPE1 M2 5X6 SUS304 1 18 862 main board PCBA 1 19 GB_CROSS_SCREWS_TYPE1 M2 5X5 SUS304 2 20 873 Copper sheet screw 2AL12 1 21 GB...

Page 9: ...6 30GF 1 4 862 left claw PA6 30GF 1 5 862 Torsional spring 65Mn 1 6 GB_FASTENER_WASHER_SMWC 2 5 sus304 2 7 GB_CROSS_SCREWS_TYPE128 ST2 2X6 5 H C N sus304 2 8 873 terminal q235 1 9 GB_CROSS_SCREWS_TYPE...

Page 10: ...NO NAME Material QTY 1 862 Battery box ABS 1 2 872 positive terminal 65Mn 2 3 872 spring terminal 65Mn 2 2 6 Electrical jobs chart 10...

Page 11: ...ch chip Note keyboard or motherboard damage can also cause cannot boot less likely and to change the contact 3 2 After startup without laser line Cause analysis 1 Instrument tilt is too large beyond t...

Page 12: ...ce is oxidation corrosion 2 The alarm ring contact surface oxidation by pollution or lead to poor contact Troubleshooting 1 Open the shell with rusty spot bearing replacement 2 Open the shell after th...

Reviews: