background image

20

7) The distance between 

a1

 and 

a2

, should be no more than

    0.75mm, otherwise send the laser level to a qualified technician  

    for repair.             

4.  Checking the Accuracy of the side Vertical beam.

For the second vertical beam, repeat the previous marking 

procedures from paragraph 1 -7.

a1

Figure #6

 # הנומת

6

X

2m

a2

 

X

X

Summary of Contents for Prolaser 4D XTRA Green

Page 1: ...Prolaser 4D XTRA Green Model No 884G Li ion 165 50m RECHARGEABLE Up to 70m 230 User Manual scan for other languages...

Page 2: ...ovatively designed for a very broad range of professional and DIY jobs including Hanging cabinets and shelves Setting floor and wall tiles Drywall installation and hanging acoustic ceilings Framing an...

Page 3: ...3 CONTENTS Features 4 Safety instructions 5 6 Battery installation Safety 7 8 Overview 9 Operating instructions 10 12 Maintenance 13 Field calibration test 14 23 Specifications 24 Warranty 25...

Page 4: ...nge Pulse mode emits pulses that can be detected by a detector Max indoor working range 30 m 100 with green goggles The max detectable range of the laser in pulse mode is 70m 230 Manual mode allows an...

Page 5: ...evel Do not look into a laser beam using magnifying optical devices such as binoculars or a telescope since it will increase the level of eye injury WARNING This product contains lead in soldered join...

Page 6: ...injury Do not drop the unit Do not use solvents to clean the laser unit Do not use in temperatures below 10 C or above 40 C 14 F to 104 F Do not operate the laser in explosive atmospheres such as fla...

Page 7: ...battery pack 2 battery packs included Installation 1 Press down the latch of the battery cover 2 Insert the Li Ion battery pack with the terminal contacts forward according to the shape of the batter...

Page 8: ...ging BLUE when fully charged 1 Charger 2 Rechargeable battery 3 LED indicator 4 Charging cable WARNING Battery can deteriorate leak or explode and can cause injury or fire 1 Do not shorten the battery...

Page 9: ...indicator e Leveling indicator f Horizontal beam selector g Vertical beams selector 2 Bottom horizontal laser beam window 3 Upper horizontal laser beam window 4 Forward vertical laser beam window V2 5...

Page 10: ...or b will turn on The leveling indicator e will start to blink slowly 3 Chose the needed laser beams using the selector buttons a Horizontal beam selector f operating by cycle Bottom beam upper beam n...

Page 11: ...hold the Pulse mode button c for 5 seconds until the leveling indicator e will start to blink fast The leveling indicator e will continue to blink fast to let you know that the beam is not leveled 4...

Page 12: ...detect the laser beams 1 The pulse mode can be activated or deactivated only in Automatic mode 2 Turn on the laser level 3 Press the Pulse mode button c to activate it The Pulse mode indicator d will...

Page 13: ...e laser level with a clean soft cloth Do not use solvents Although the laser level is dust and dirt resistant to a certain degree don t store in dusty places as long term exposure may damage internal...

Page 14: ...endicularity between the 2 vertical beams 1 Checking the Height Accuracy of the cross created by the side vertical and Horizontal lines Up and down deviation 1 Set up the laser on a table or on the fl...

Page 15: ...Reposition the laser and verify that the 2 vertical lines pass through a1 and c1 7 Mark on wall B the center of the cross beams as b1 see figure 2 A B Figure 1 C a1 0 5m c1 X 2m X approximately 5m A B...

Page 16: ...erify that the vertical line passes through a1 and b1 10 On wall B mark the center of the cross beams as b2 see figure 3 11 Turn the laser 180 Reposition the laser and verify that the 2 vertical lines...

Page 17: ...ld be no more than 2 25 mm otherwise send the laser level to a qualified technician for repair 15 Mark the dots only with laser beams leveled leveling indicator e not blinking Repeat the procedure for...

Page 18: ...e both verticals and bottom horizontal laser beams to be projected 4 Direct the cross lines of the horizontal beam and the forward vertical beam towards wall A 5 Repeat the previous marking procedures...

Page 19: ...4 Turn the device ON and choose to project the vertical forward beam towards the plumb line 5 Turn the laser so the vertical beam will merge with the plumb line below the hanging point 6 Mark point a2...

Page 20: ...more than 0 75mm otherwise send the laser level to a qualified technician for repair 4 Checking the Accuracy of the side Vertical beam For the second vertical beam repeat the previous marking procedu...

Page 21: ...ON and choose to project the forward and the side vertical beams 3 Mark the center of the side vertical beam in 3 places Point a1 on the left wall A in the middle of the vertical line Point b1 on the...

Page 22: ...through c1 on the table and the forward laser beam passes through the marks a1 and b1 on the walls A and B respectively 6 Mark as c3 the center of the side vertical beam on wall C at the same height a...

Page 23: ...23 7 The distance between c2 and c3 should be no more than 1 15mm otherwise send the laser level to a qualified technician for repair c3 X c1 X X a1 2 5m 2 5m A b1 X B C Figure 8 5m X c2...

Page 24: ...5mm m 0 00015in in Self leveling Range 4 Laser line width 2 mm 0 5mm 5m 0 10 0 02 at 20 Wavelength 510 530nm Laser Class II Power supply 2600mAh Li Ion battery 7 4V Battery life Up to 5 5 hours of con...

Page 25: ...urchase Model 884G The serial number sticker is positioned on the bottom horizontal laser window frame near the battery compartment CE CONFORMITY CERTIFICATE This product meets the standards of the El...