14
FIELD CALIBRATION TEST
The Laser Level leaves the factory fully calibrated. Kapro
recommends that the level is checked regularly, and after
the unit has been dropped or mishandled.
Horizontal Line Calibration Test
1. Set up the Laser Level on a flat, vibration-free
surface or tripod as near as possible to a long wall.
2. Unlock the safety lock by setting the switch to ON.
3. Press the Beam Selector button on the keypad to
generate a horizontal beam on the wall.
4. Make two marks through the laser line on the
wall, one very close to the Laser Level and one as far
away as possible.
5. Lock the safety lock, reposition the Laser Level (at the
same height) as near as possible to the far mark on the
wall. Repeat steps 2 and 3.
6. Measure the height difference between the
laser line and the two marks previously made on the wall.
7. If the two measurements are identical, then the
laser level is calibrated.
Summary of Contents for Prolaser 3D All-Lines 883
Page 1: ...Prolaser 3D All Lines Model No 883 User Manual 4AA 200 60m INCLUDED...
Page 18: ...18 883 Prolaser 3D All Lines Kapro 883 Prolaser 3D All Lines 4AA 200 60m INCLUDED RU...
Page 19: ...19 20 21 22 23 24 25 26 27 28 29 30 31 32 33...
Page 20: ...20 360 360 4 20 60 1 4 5 8 0 2 883 Prolaser 3D All Lines 4 AA...
Page 21: ...21 883 Prolaser 3D All Lines 2 IEC Prolaser 3D...
Page 22: ...22 A B C D E 1 4 F 5 8 G H...
Page 23: ...23 883 Prolaser 3D All Lines 4 AA...
Page 24: ...24 883 Prolaser 3D All Lines OFF 1 LOCK 2 LOCK LED 1 2...
Page 25: ...25 ON 3 4 3...
Page 26: ...26 A B Low Power C Manual Lock D Beam Selector Pulse Mode for use with detector...
Page 27: ...27 Beam selector 4 4 LED 3...
Page 28: ...28 20 C 4 F 60 C 140 F...
Page 29: ...29 Prolaser 883 All Lines...
Page 30: ...30 Kapro 1 2 3 Output Control 4 5 2 3...
Page 31: ...31 6 7 1 2 1 3 4 Output Control 5 6...
Page 33: ...33 No 883...
Page 34: ...34...
Page 35: ...35...
Page 36: ...36 2014 Kapro Industries Ltd...