KPC-9612 Version 5.2 July 19, 1994
30
• MCOM ON|OFF
{ON/ON}
When ON, monitored packets include connect frames <C>, disconnect frames <D>, disconnected
mode frames <DM>, and unnumbered acknowledgments <UA>. In addition, the following infor-
mation will be added to monitored information frames as appropriate:
<UI> Unconnected information frame
<Is> Information frame (connected); s = send sequence number
See also: ax2512v2, monitor, mresp
• MCon ON|OFF
{OFF/OFF}
When OFF and connected to another station, you will see only data being sent to you by the other
station. When OFF and not connected, normal monitoring will occur based on the settings of other
"monitor" commands. When ON, all eligible packets will be monitored whether you are connected
or not.
See also: monitor, streamca, streamev
• MHClear
{immediate command}
This command clears the stations heard log.
See also: mheard
MHeard [
S|L]
{immediate command}
This command will display a list of stations heard by your KPC-9612 recently. An asterisk (*) indi-
cates that the station was heard through a digipeater. The date/time the station was last heard is
also displayed. If the
S option is used (
MHEARD S
) only the callsigns of the stations heard will be
displayed. If the
L option is used, all call-signs contained in the received packet, including digipeat-
er paths, will be displayed.
NOTE: MHEARD logging will be disabled if PASSALL is ON.
See also: daytime, mhclear
MODe [
b][,[p],[d],[s]]
(b = 1200, 1800, 2400, 4800, 9600, 19200;
p = EVEN, ODD, NONE; d = 7, 8; s = 1, 2)
The MODE command is used to set the serial port parameters of the KPC-9612 for communiation
with the attached terminal. The
b parameter sets the terminal baud rate, p sets the parity, d is the
number of data bits, and
s is the number of stop bits. Entering only a baud rate (b) will change
the baud rate, leaving the other parameters unchanged. When
b is set to 0, the KPC-9612 will per-
form an autobaud routine when powered up. To change the parity without any other changes, you
must either enter the baud rate and the parity or enter the comma before the parity. For example,
to change only the number of data bits, you could enter the command
MODE ,,7
.