Installation Manual
P600 ioProx Long Range Proximity Reader
24
DN5084-0804
4. The LED must turn green when connecting the “BRN” or LED terminal to the reader’s
ground. If not, return the reader.
Reader BUZZER doesn’t sound
1. Verify that the “blue” wire or Buzzer terminal is connected to the door controller's output.
2. Verify that the door controller's output programming is ok.
3. The BUZZER must be heard when connecting the “BLU” or Piezo terminal to ground. If not,
return the reader
Reader doesn't read correct card number
1. Verify that the XSF/W26 switch is in the correct position.
2. Verify that the door controller's reader type (XSF or Weigand 26 bits) is properly pro-
grammed.
3. Verify that the correct proximity card is being used (P10SHL, P20DMG, P30DMG, P40KEY).
4. Verify that there is communication between the reader and the door controller.
Reader works intermittently
1. Is it working in a harsh environment such as machine shop or construction site?
2. Is there ice buildup on the printed circuit or antenna posts? If so, return the reader.
3. Is there water leakage or evidence of water on the printed circuit or antenna posts? If yes,
return the reader.
4. Is the power supply dedicated?
5. Is the reader installed near an air conditioning or HVAC unit, which comes on (causing induc-
tive kickback) at different times of day?
6. Is there an intercom unit located near the reader, whose wires or operation may interfere?
Summary of Contents for ioProx P600
Page 1: ...DN5084 0804 P600 ioProx Long Range Proximity Reader Installation Manual ...
Page 6: ...Installation Manual P600 ioProx Long Range Reader vi DN5084 0804 ...
Page 12: ...Installation Manual P600 ioProx Long Range Proximity Reader 12 DN5084 0804 ...
Page 20: ...Installation Manual P600 ioProx Long Range Proximity Reader 20 DN5084 0804 ...
Page 25: ......