Duct Air Leakage Tester Operation Manual Ver.3 

 

 

6 Warranty and Service 

6.1. Product Warranty 

The  limited warranty  set forth  below is  given  by  KANOMAX GROUP  COMPANIES  with respect to the 

KANOMAX  brand  Duct  Air  Leakage  Tester  and  other  accessories  (hereafter  referred  to  as  “PRODUCT”) 
purchased directly from KANOMAX GROUP COMPANIES or from an authorized distributor.   

Your PRODUCT, when delivered to you in new condition in its original container, is warranted against defects 

in materials or workmanship as follows: for a period of two (2) year from the date of original purchase, defective 
parts  or  a  defective  PRODUCT  returned  to  KANOMAX  GROUP  COMPANIES,  as  applicable,  and  proven  to  be 
defective upon inspection, will be exchanged for a new or comparable rebuilt parts, or a refurbished PRODUCT as 
determined  by  KANOMAX  GROUP  COMPANIES.  Warranty  for  such  replacements  shall  not  extend  the  original 
warranty period of the defective PRODUCT. 

This limited warranty covers all defects encountered in normal use of the PRODUCT, and does not apply 

in the following cases: 
(1)

 

Use of parts or supplies other than the PRODUCT sold by KANOMAX GROUP COMPANIES, which cause 
damage to the PRODUCT or cause abnormally frequent service calls or service problems. 

(2)

 

If any PRODUCT has its serial number or date altered or removed. 

(3)

 

Loss  of  damage  to  the  PRODUCT  due  to  abuse,  mishandling,  alternation,  improper  packaging  by  the 
owner,  accident,  natural  disaster,  electrical  current  fluctuations,  failure  to  follow  operation, 
maintenance or environmental instructions prescribed in the PRODUCT's operation manual provided by 
KANOMAX GROUP COMPANIES, or service performed by other than KANOMAX GROUP COMPANIES. 

NO  IMPLIED  WARRANTY,  INCLUDING  ANY  IMPLIED  WARRANTY  OF  MERCHANTABILITY  OR  FITNESS  FOR  A 
PARTICULAR PURPOSE, APPLIES TO THE PRODUCT AFTER THE APPLICABLE PERIOD OF THE EXPRESS LIMITED 
WARRANTY  STATED  ABOVE,  AND  NO  OTHER  EXPRESS  WARRANTY  OR  GUARANTY,  EXCEPT  AS  MENTIONED 
ABOVE, GIVEN BY ANY PERSON OR ENTITY WITH RESPECT TO THE PRODUCT SHALL BIND KANOMAX GROUP 
COMPANIES. KANOMAX GROUP COMPANIES SHALL NOT BE LIABLE FOR LOSS OF STORAGE CHARGES, LOSS 
OR CORRUPTION OF DATA, OR ANY OTHER SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES CAUSED BY 
THE  USE  OR  MISUSE  OF,  OR  INABILITY  TO  USE,  THE  PRODUCT,  REGARDLESS  OF  THE  LEGAL  THEORY  ON 
WHICH  THE  CLAIM  IS  BASED,  AND  EVEN  IF  KANOMAX  GROUP  COMPANIES  HAS  BEEN  ADVISED  OF  THE 
POSSIBILITY OF SUCH DAMAGES.IN NO EVENT SHALL RECOVERY OF ANY KIND AGAINST KANOMAX GROUP 
COMPANIES  BE  GREATER  IN  AMOUNT  THAN  THE  PURCHASE  PRICE  OF  THE  PRODUCT  SOLD  BY  KANOMAX 
GROUP  COMPANIES  AND  CAUSING  THE  ALLEGED  DAMAGE.WITHOUT  LIMITING  THE  FOREGOING,  THE 
OWNER  ASSUMES  ALL  RISK  AND  LIABILITY  FOR  LOSS,  DAMAGE  OF,  OR  INJURY  TO  THE  OWNER  AND  THE 
OWNER'S  PROPERTY  AND  TO  OTHERS  AND  THEIR  PROPERTY  ARISING  OUT  OF  USE  OR  MISUSE  OF,  OR 
INABILITY  TO  USE,  THE  PRODUCT  NOT  CAUSED  DIRECTLY  BY  THE  NEGLIGENCE  OF  KANOMAX  GROUP 
COMPANIES.  THIS  LIMITED  WARRANTY  SHALL  NOT  EXTEND  TO  ANYONE  OTHER  THAN  THE  ORIGINAL 
PURCHASER OF THE PRODUCT, OR THE PERSON FOR WHOM IT WAS PURCHASED AS A GIFT, AND STATES THE 
PURCHASER'S EXCLUSIVE REMEDY. 

6.2. After service 

 

When  you  have  a  problem with your  instrument,  please  check out  the “Common  Trouble  Shooting” 
section first. 

 

If that does not help, please contact your local distributor, or contacts on the last page. 

Summary of Contents for DALT 6900

Page 1: ...Leakage Tester Operation Manual Ver 3 OPERATION MANUAL Version 3 Duct Air Leakage Tester Model DALT 6900 Be sure to read this manual thoroughly before using the instrument Please keep this manual as a service reference ...

Page 2: ...ain unit 6900 1 Flow Grid 1 Low flow nozzle 1 Ø6 Silicone tube white 1 Duct connection hose 1 Power cord 1 Container 1 Ø 6 Silicon tube blue 1 Ø 6 Silicon tube red 1 Calibration certificate 1 Optional Extras ITEM Model QTY Static pressure probe 6700 08 Dust proof cover 6900 COVER Calibration Certificate AFCAL 6900 ...

Page 3: ...roduct Warnings in this classification indicate a risk of damage to the product that may void the product warranty if This symbol indicates a condition that requires caution including danger The subject of each caution is illustrated inside the triangle This symbol indicates a prohibition Do not take the prohibited action shown inside or near this symbol This symbol indicates a mandatory action A ...

Page 4: ...t for the ring 200kgs Otherwise instrument Duct Air Leakage Tester Operation Manual Ver 3 CAUTION Always unplug when the instrument not in use Failure to do so may cause an electric shock a fire or circuit damage Do not use or leave the instrument in a high temperature high humidity or dusty environment Do not leave the instrument under direct sunlight Otherwise the instrument may not function pro...

Page 5: ...t connection 9 3 2 High flow testing 10 3 3 Low flow testing 11 4 OperatingInstructions 12 4 1 Power On 12 4 2 Accreditation menu 12 4 3 Measure menu 15 4 4 Setting menu 16 4 5 My Data menu 17 4 6 USB menu 18 4 7 About menu 18 5 Error and Troubleshooting 19 6 Warranty and Service 20 6 1 Product Warranty 20 6 2 After service 20 Appendix1 Leakage Testing Standards 22 Appendix2 Fan Performance Graph ...

Page 6: ...lay and friendly Man machine interface will make operation convenient and easier 1 1 Product features Duct air leakage testing under positive or negative flow Compliant with the following standards EN1507 2006 EN12237 2003 Eurovent 2 2 DW 143 SMACNA Standard AABC Standard GB50243 2003 2016 Wide air flow testing range two measuring tools ensure the test accuracy Accreditation result will determine ...

Page 7: ...ure Ranges 32 to 140 F 0 to 60 C Accuracy 1 F 0 5 C Resolution 0 1 F 0 1 C Absolute Pressure Ranges 20 6 to 38 3 in Hg 70 to 130kPa Accuracy 2 of Reading Resolution 0 1 in Hg 0 1 kPa Power Source DALT 6900 does not operate with temporary power from an insufficient power supply DALT 6900 0E 100 120V 1 Phase 50 60Hz 16A DALT 6900 1E 200 240V 1 Phase 50 60Hz 10A Dimensions Main unit 420 Foot print Sq...

Page 8: ...re Fan Speed Control Duct Air Leakage Tester Operation Manual Ver 3 Outlook Structure Fan Stop Switch Fan Run Switch Power On Off Display screen Temperature Power Motor Control Low flow nozzle Controller Container Power source Fan 8 Negative pressure Positive pressure Static Pressure Fan Inlet Fan Outlet ...

Page 9: ...ing duct surface to ensure it s available and within the input range Connect the testing duct to the Tester 1 Position the DALT 6900 unit as close to the remaining opening in the ductwork as possible to minimize the flexible tubing needed Minimize bends in the flexible tubing to reduce the pressure loss giving the best performance 2 Fit one end of the flexi tube with adapter spigot to the6900 Make...

Page 10: ...inet And same color hose tap connection please Noted Hard push cam lock arms at the same time when locking the cam lock 1 Duct testing under Positive pressure Connect the flexible tubing to the outlet side of the flow grid pressure tap then tight lock 2 Duct testing under Negative pressure Connect the flexible tubing to the flow inlet side of the Fan then tight lock High flow Duct testing under po...

Page 11: ...the Differential pressure flow port of the controller cabinet And same color hose tap connection please 1 Duct testing under Positive pressure Connect the flexible tubing to the flow outlet side of the nozzlethen tight lock 2 Duct testing under Negative pressure Connect the flexible tubing to the flow inlet side of the Fan then tight lock Low flow Duct testing under positive pressure Low flow Duct...

Page 12: ...ehind the controller cabinet Power the controller on by plugging in the power cord Press Power On of the Application items in Accreditation set the Accreditation Standard for Duct leakage as steps according to the set standard and save testing data as request Application items in Measure airflow pressure temperature and atmosphere Application items in Setting date time testing mode unit and other ...

Page 13: ...Leakage Tester Operation Manual Ver 3 Click for Testing standard selection inputting Duct Surface Click to Test time setting Click for adjusting static pressure in duct Press START for motor start running Switch Fan speed control pressure in Duct to access the Application menu selection NEXT NEXT 13 Surface Area to Test time setting for adjusting static pressure in duct for motor start running Fan...

Page 14: ...ting begin NEXT Duct Air Leakage Tester Operation Manual Ver 3 After the Measurement please press STOP button of Blower Control to stop the Blower hen pressure statically click for time displaying the static pressure in duct Through after the setting time output display the testing result Click for data saving NEXT SAVE Measure Accreditation My Data USB 14 Through after the setting time output dis...

Page 15: ...ct Air Leakage Tester Operation Manual Ver 3 Measure items include airflow static pressure temperature and atmosphere Press to enter the selected When pressure is adjusted to the request click for start Airflow testing Press for end the airflow testing for motor start running for adjusting Air flow will be real time display during testing Press STOP for Fan stop running to access the Application m...

Page 16: ...own below 1 Date setting Click Date for editing setting Duct Air Leakage Tester Operation Manual Ver 3 nu application items include Date Time STD ACT Temperature Atmosphere Air flow and Click for data saving Set Press or for modifying data 16 Temperature Atmosphere Air flow and Click for data saving Press or for modifying data ...

Page 17: ...data reviewing 3 Through Delete range settings for deleting selected data 4 Exit Click for Exiting the data browsing interface Duct Air Leakage Tester Operation Manual Ver 3 for page turning browsing Click the serial No on upper right corner for data reviewing range settings for deleting selected data for Exiting the data browsing interface Del 17 ...

Page 18: ...oduction menu describing the main Duct Air Leakage Tester Operation Manual Ver 3 The data record can be output by USB disk disk to USB connector it will be found by the system and all the saved data will be the time of output will be long Please clean up the U Click About for entering the introduction menu describing the main parameters of the instrument 18 disk to USB connector it will be found b...

Page 19: ...ure External disturbances Check around away from the possible external disturbances re start the Controller Capacitive touch screen only recognizesa fingertouch Finger touch directly Touch screen failure Connect with manufacturer 4 Temperature display wrong Temperature line is not connected or poor connect Check and well connect the temperature line 5 Air flow range displayed wrong Testing tool se...

Page 20: ...ODUCT s operation manual provided by KANOMAX GROUP COMPANIES or service performed by other than KANOMAX GROUP COMPANIES NO IMPLIED WARRANTY INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE APPLIES TO THE PRODUCT AFTER THE APPLICABLE PERIOD OF THE EXPRESS LIMITED WARRANTY STATED ABOVE AND NO OTHER EXPRESS WARRANTY OR GUARANTY EXCEPT AS MENTIONED ABOVE GIVEN BY A...

Page 21: ... expense if the instrument s performance is found to be recoverable by providing the repair Replacement parts are available for a minimum period of five 5 years after termination of production This storage period of replacement parts is considered as the period during which we can provide repair service For further information please contactyour local distributor or contacts on the last page PRODU...

Page 22: ...expected leakage rates for sealed and unsealed ductwork duct leakage test procedures recommendations on use of leakage testing types of test apparatus and test setup and sample leakage analysis 6 AABC US Associated Air Balance Council AABC Standard 7 GB50243 2003 2016 GB Quality acceptance regulation of Ventilation and Air conditioning work 1 EU Standards EN12237 Air Tightness Class Air Leakage Li...

Page 23: ... Class B 1000 750 20 0 009 P High pressure Class C 2000 750 40 0 003 P 4 EU Standards Eurovent 2 2 Air Tightness Class Air leakage limit fmax m3 s m2 A 0 027 P 1000 B 0 009 P 1000 C 0 003 P 1000 5 US Standards SMACNA Duct Class 1 2 1 2 inwg 3 inwg 4 6 10 inwg Seal Class C B A Sealing Applicable Transverse Joints Only Transverse Joints and Seams Joints Seams and All Wall Penetrations Leakage Class ...

Page 24: ... and CAV terminal boxes tested with upstream ductwork 4 00 WC 995Pa 1 8 Supply ducts for VAV and CAV systems 4 00 WC 995Pa 1 9 Dual duct systems both hot duct and cold duct 6 00 WC 1495Pa 1 10 High pressure induction system 6 00 WC 1495Pa 0 5 11 Exhaust systems for labs with air valves 6 00 WC 1495Pa 0 5 12 Grease duct Systems 4 00 WC 995Pa 0 0 13 Supply return and exhaust ductwork located outdoor...

Page 25: ...nd medium pressure composite material duct and Illegal orchid form of nonmetallic duct should be 50 of the regulated leakage value of the rectangle duct 2 The allowable air leakage of brick concrete duct should be no more than 1 5times regulated leakage value of the rectangle duct 3 Ventilation dedusting with low temperature air supply system should be according to and comply with the standard for...

Page 26: ...26 Duct Air Leakage Tester Operation Manual Ver 3 Appendix2 Fan Performance Graph 0 2 4 6 8 10 12 0 50 100 150 200 250 300 350 400 Static Pressure in H 2 O Volume Flow CFM ...

Page 27: ...for use Take special care with joints sealing Blank off all open ends Static Pressure Tube Duct Air Leakage Tester Operation Manual Ver 3 Installation Instruction access openings and difficult joints with test rig running leaks should be audible particularly if wet over joints can help locate leaks paint over joints and look for bubbles placed inside ductwork obtain permission for use Take special...

Page 28: ...www kanomax co jp E Mail sales kanomax co jp China Shenyang Kano Scientific Instrument Co Ltd 1314 1315 56 39 Yellow River North Street HuangGu District ShenYang City 110035 China TEL 86 24 23846440 83951688 83951788 FAX 86 24 23846440 820 URL http www kanomax com cn E Mail sales kanomax com cn Copyright Kanomax USA Inc All rights reserved 2016 No copying distribution publication modification or i...

Reviews: