Kanomax 6813 User Manual Download Page 1

 

 

 

   

 

219 Route 206                                                                         Phone:   1-800-247-8887 
PO Box 372                                                                    

Fax:       (973) 786-7586 

Andover, NJ 07821 USA                                                        [email protected] 

 

 

6813

 User Manual, PN 10283 

                                          Kanomax USA, Inc 

Rev 2.0, 24-Nov-2009 

                                                    www.kanomax-usa.com 

Copyright © 2008, Kanomax USA, Inc.                      

    

Page 24 of 24

 

TM 

 
 
 
 

 

 
 

 

Kanomax USA, Inc.

 

219 Route 206 

PO Box 372 

Andover, New Jersey 07821 

  USA 

(800) 247-8887 

Fax: (973) 786-7586 

[email protected]

 

 

 
 

www.kanomax-usa.com

 

 
 
 
 

 
 

Copyright © 2008, Kanomax USA, Inc 

 

 

 

 

219 Route 206                                                                         Phone:   1-800-247-8887 
PO Box 372                                                                    

Fax:       (973) 786-7586 

Andover, NJ 07821 USA                                                        [email protected] 

 

 

6813

 User Manual, PN 10283 

                                          Kanomax USA, Inc 

Rev 2.0, 24-Nov-2009 

                                                    www.kanomax-usa.com 

Copyright © 2008, Kanomax USA, Inc.                      

    

Page 1 of 24

 

TM 

 
 

 

 

 
 

Model 6813

™ 

THERMO-ANEMOMETER 

 

 
 
 

User Manual 

 
 
 
 
 
 
 
 
 
 
 
 
 

TM 

Summary of Contents for 6813

Page 1: ...x USA Inc 219 Route 206 PO Box 372 Andover New Jersey 07821 USA 800 247 8887 Fax 973 786 7586 info kanomax usa com www kanomax usa com Copyright 2008 Kanomax USA Inc 219 Route 206 Phone 1 800 247 8887 PO Box 372 Fax 973 786 7586 Andover NJ 07821 USA info kanomax usa com 6813 User Manual PN 10283 Kanomax USA Inc Rev 2 0 24 Nov 2009 www kanomax usa com Copyright 2008 Kanomax USA Inc Page 1 of 24 TM ...

Page 2: ...ng life 219 Route 206 Phone 1 800 247 8887 PO Box 372 Fax 973 786 7586 Andover NJ 07821 USA info kanomax usa com 6813 User Manual PN 10283 Kanomax USA Inc Rev 2 0 24 Nov 2009 www kanomax usa com Copyright 2008 Kanomax USA Inc Page 23 of 24 TM CALIBRATION To maintain your instrument in top working order we recommend that you send it back to us for calibration each year beginning one year after purc...

Page 3: ...86 7586 Andover NJ 07821 USA info kanomax usa com 6813 User Manual PN 10283 Kanomax USA Inc Rev 2 0 24 Nov 2009 www kanomax usa com Copyright 2008 Kanomax USA Inc Page 3 of 24 TM Warranty This product is fully warranted against defective materials and or workmanship for a period of one year after purchase provided it was not improperly used For your protection please use this product as soon as po...

Page 4: ...esolution Air Velocity 1 ft min or 0 01 m sec Temperature 0 1 F or 0 1 C Operating Temperature Instrument 32 to 125 F 0 to 50 C Air Probes 4 to 212 F 20 to 100 C Power Supply 3 AA alkaline batteries Battery Life Approx 150 hours without backlight Battery check Automatic low battery display Display 0 5 LCD 4 digits with LED backlight 219 Route 206 Phone 1 800 247 8887 PO Box 372 Fax 973 786 7586 An...

Page 5: ...as Units shown on LCD Display 219 Route 206 Phone 1 800 247 8887 PO Box 372 Fax 973 786 7586 Andover NJ 07821 USA info kanomax usa com 6813 User Manual PN 10283 Kanomax USA Inc Rev 2 0 24 Nov 2009 www kanomax usa com Copyright 2008 Kanomax USA Inc Page 5 of 24 TM Options Available Protective Boot and Splash Proof Seal for the Instrument USB Communications RS232 Communications Analog 0 5 Volt Outpu...

Page 6: ...BE 219 Route 206 Phone 1 800 247 8887 PO Box 372 Fax 973 786 7586 Andover NJ 07821 USA info kanomax usa com 6813 User Manual PN 10283 Kanomax USA Inc Rev 2 0 24 Nov 2009 www kanomax usa com Copyright 2008 Kanomax USA Inc Page 19 of 24 TM Click on File Properties You will see the window shown below Click on the Settings tab and then click on ASCII Setup as shown below Make sure that Append line fee...

Page 7: ... PN 10283 Kanomax USA Inc Rev 2 0 24 Nov 2009 www kanomax usa com Copyright 2008 Kanomax USA Inc Page 7 of 24 TM SECTION 2 SWITCH FUNCTIONS Pressing the ON OFF key switches the instrument ON Hold down the key for 2 seconds to switch the unit OFF The unit will automatically power off after 30 minutes without any key presses To disable auto power off hold down the power button during turn on The uni...

Page 8: ...s displayed 4SEC An average value of airspeed measurements during the preceding 4 seconds is displayed 8SEC An average value of airspeed measurements during the preceding 8 seconds is displayed 16 S An average value of airspeed measurements during the preceding 16 seconds is displayed Note The sample rate for temperature readings is always 2 seconds 219 Route 206 Phone 1 800 247 8887 PO Box 372 Fa...

Page 9: ... 247 8887 PO Box 372 Fax 973 786 7586 Andover NJ 07821 USA info kanomax usa com 6813 User Manual PN 10283 Kanomax USA Inc Rev 2 0 24 Nov 2009 www kanomax usa com Copyright 2008 Kanomax USA Inc Page 9 of 24 TM Press the MAX MIN key to record and display the maximum reading for either temperature or air velocity The maximum reading display will alternate with the letter H displayed with the sample r...

Page 10: ...DIX A LCD DISPLAY SYMBOLS APPENDIX B BATTERY REPLACEMENT 219 Route 206 Phone 1 800 247 8887 PO Box 372 Fax 973 786 7586 Andover NJ 07821 USA info kanomax usa com 6813 User Manual PN 10283 Kanomax USA Inc Rev 2 0 24 Nov 2009 www kanomax usa com Copyright 2008 Kanomax USA Inc Page 15 of 24 TM You are now ready to capture the data being measured by your instrument Please refer to Appendix G Viewing a...

Page 11: ... port number You only need to do this once For Windows users open the Windows Device Manager found in Control Panel and verify that a USB serial port exists as shown below 219 Route 206 Phone 1 800 247 8887 PO Box 372 Fax 973 786 7586 Andover NJ 07821 USA info kanomax usa com 6813 User Manual PN 10283 Kanomax USA Inc Rev 2 0 24 Nov 2009 www kanomax usa com Copyright 2008 Kanomax USA Inc Page 11 of...

Page 12: ...Volts to Air Velocity in Feet per Minute multiply by 2000 For example an analog output of 2 375 Volts on the green wire means that the instrument is measuring an air velocity of 4750 feet per minute FPM 2 375 Volts 2000 4750 FPM To convert from Volts to Temperature in degrees Celsius C multiply by 20 and subtract 20 For example an analog output of 3 458 Volts on the white wire means that the instr...

Reviews: