Summary of Contents for 6750

Page 1: ...TABmaster Mini Model 6750 User s Manual ...

Page 2: ...rflow is detected by the 16 individual pressure sensors and then the average result is displayed You can also set the atmospheric pressure manually to minimize differences due to changes in atmospheric pressure at the time of measurement List of Components Standard Item name Composition Model Quantity TABmaster Mini Main Body Indicator Indicator fixing jig Extension rod Carrying case Hood USB cabl...

Page 3: ...ol indicates a prohibition Do not take the prohibited action shown inside of or near this symbol e g the disassembly prohibition symbol is shown on the left This symbol indicates a mandatory action A specific action is given near the symbol Danger Never bring the instrument to a flammable gas atmosphere The heated instrument may cause a fire or explosion Use the instrument properly by carefully fo...

Page 4: ...The instrument may not function properly out of the specified operating conditions Remove the batteries from the battery compartment when storing the instrument for a long period Do not leave exhausted batteries in the battery compartment When inserting batteries be sure to insert batteries with the polarity facing the correct direction Failure to do this may cause battery leakage or malfunction D...

Page 5: ...screen with a sharp pointed object or with excessive pressure It may cause distortion of the screen or a malfunction A rapid temperature change may cause a malfunction of the screen When storing the instrument put the instrument in the carrying case and keep it in a place with an ambient temperature of 10 to 50 and no condensation Do not dispose of the instrument as household waste Please note tha...

Page 6: ...ning the Power ON OFF 12 Operating the Instrument 13 Chapter 4 Taking a Measurement 14 Main Screen 14 Taking a Measurement and Storing the Data 14 Chapter 5 Menu Operation 16 Displaying the Menu Screen 16 IDset ID Setting 16 Display Read 17 Delete Delete 18 UPlink Send 19 Print Settings Error Bookmark not defined Chapter 6 Other Settings 23 Settings Screen 23 Setting and Storing the Airflow Unit 2...

Page 7: ...ain Body External structure Internal structure Sampling Tube Matrix Measures airflow at 16 measuring points Main body Indicator Hood Support pole Rectifying honeycomb Pole mounting hole Airflow detecting port Indicator connector Extension rod fixing screw Airflow measuring point Extension rod Main body indicator cable ...

Page 8: ...nsion Rod Liquid crystal display Operation button Battery Cover Cover Lock Main body connector POWER Button Frame Support Pole Clear hood Hood edge urethane rubber Extension rod Indicator Fixing jig Grip Power supply terminal POWER button ...

Page 9: ...o the pole mounting hole see Fig Insert the other end of the support pole into the corner of the frame See Fig Refer to Fig for the position of the other 3 poles and repeat the above steps The support poles must be assembled crosswise To remove a support pole reverse the assembly steps Adjusting the Extension Rod Release the screw lock of the extension rod Extend the length of the rod as required ...

Page 10: ...ch the jig to the extension rod Then tighten the knob to fix the jig in place Affix the indicator to the jig as shown below Loosen the nut to adjust the angle of the indicator Set the desired angle and tighten the nut to fix it in place Connecting the Main Body and Indicator Insert the Main Body Indicator cable to the indicator connector of the main body and to the main body connector of the indic...

Page 11: ...AA batteries as shown in the battery compartment New alkaline batteries or rechargeable nickel hydrogen batteries can be used Do not use different types of batteries at the same time It will cause a battery leak and possible malfunction When the battery cover is slid back to the original position Fig it will automatically lock When the power is supplied using batteries the remaining battery life i...

Page 12: ...Turning the Power On Hold down the POWER button at the top of the indicator The atmospheric pressure setting screen will automatically be displayed Start Screen Atmospheric Pressure Setting Screen Main measurement screen Turning the Power OFF In any mode holding down the POWER button for more than 2 seconds will turn the power off The screen is automatically displayed Press Atmospheric Pressure 1 ...

Page 13: ...efinition of the Operation Button on the Indicator Starts a measurement on the measurement main screen Stops the measurement on the measurement main screen Cancels the current measurement Moves back to the previous screen Stores the setting Moves to the setting menu of the current item Moves to the main menu from the main measurement menu by holding down the button for 2 seconds Changes the value ...

Page 14: ...ain screen for measurement a Airflow Graph Area b Airflow and Temperature Display Area displays the measured data of airflow and temperature c Power Supply Mode displays the current power supply mode AC adaptor or battery mark d ID No displays the ID number to store airflow measurement data and the data number e Operation button displays the contents of the button operations Measurement and Storin...

Page 15: ...d Note The displayed airflow value is an instantaneous value of every second To interrupt the ongoing measurement press the 停止 button The final measurement value will be displayed To store the value of the interrupted measurement press the 保存 button When the data is saved the Data Number is automatically increased by 1 ...

Page 16: ...s can be set 1 ID Set ID Setting 2 Display Read data 3 Delete Delete data 4 UPlink Send data 5 Print Print data 6 Set Bluetooth ID Set ID Setting Up to 60 IDs can be set In a single ID up to 100 measuring data can be saved On the menu screen press or to select ID setting and tap to move on the ID Setting screen When 1 ID Setting is selected tap or to change the ID value Select 1 ID setting ...

Page 17: ...tional new ID cannot be created Display Read data Press or on the menu screen and select display Read Press to move on the data reading screen Tap to go back to the menu screen of the airflow value means airflow direction Press to select an item Press or to change the values of ID and or No Select 2 New ID Hold down No data is stored in a new ID Tap ...

Page 18: ...te by No are available Tap to go back to the Delete screen Tap to go back to the menu screen Delete Delete All This function deletes all IDs and measurement data under the all IDs Press or to select 1 全削除 Delete All Hold down for 2 seconds to display the confirmation message Press to delete all Press to cancel Delete All Press ...

Page 19: ...D number to be deleted Press or to select the Data number to be deleted Hold down for 2 seconds to display the confirmation message Press to delete the selected data Press to cancel to delete UPlink Send data In prior to this setting be sure to confirm the connection of the communication cable and the PC and to execute the provided Measuring Software Model 6750 40 ...

Page 20: ...tart the connection between the main body and the PC If an error occurs in a process of connection the Error Connect Error as shown lower left will be displayed Print Setting In prior to printing confirm the following points Be sure to use the designated printer and printer cable For details refer to the user s manual DPU S245 Printer Make sure that the baud rate of the printer is set to 19200 Con...

Page 21: ...Print by ID Print by ID Entry Press to go back to the setting screen Set the Start ID number by pressing or Hold down for 2 seconds to display the Print message Press to cancel Print by Data Entry Select 2 Print by No Print by Data Entry and press to move to the setting screen After that follow the same process as the above Print by ID Print by ID Entry Press Press Screen while printing ...

Page 22: ...ing screen Hold down for 2 seconds to display the Model name serial number Hold down for 2 seconds to cancel To connect from OS device iPhone iPad to 6750 can operate 6750 from OS device and it can send the data with e mail Need to download TABmaster s from App Store in advance the connection ...

Page 23: ...ied a Airflow unit setting m3 h CFM Default unit m3 h b Temperature unit setting F Default unit c Atmospheric pressure unit setting kPa inHg Default unit kPa d K factor setting 0 500 to 1 500 Default value 1 000 Setting and Storing the Airflow Unit Select 1 風量 Airflow and press button to display the list of m3 h and CFM The currently selected unit is a highlighted in white as shown in the lower ri...

Page 24: ...list of kPa and inHg The currently selected unit is highlighted in white as shown in the lower right figure Press or to select the unit and press to store the setting of the unit Pressing will cancel the setting and go back to the previous screen Setting and Storing the K Factor Select 4 K factor and press button to display the K factor setting Press to store the setting value Press to cancel the ...

Page 25: ... of settable K factor is from 0 500 to 1 500 at 0 001 intervals Note If is pressed when displaying 1 500 the setting will be changed to 0 500 if is pressed wen displaying 0 500 the setting will be changed to 1 500 ...

Page 26: ...ation Bluetooth Digital Output USB Power Supply AA Battery x 4 AC adaptor Option Dimension of the hood 355 355 mm Weight 1 5 kg Accessories Indicator Indicator Fixing Jig Extension Rod Carrying Case Hood 355 355 mm USB Cable Main Body Indicator Cable 2m AA Batteries 4 pieces Measuring software CD R User s Manual this document Insp document Inspection Report Options Spare Hood 6750 01 Hood Edge Ure...

Page 27: ...cannot be created The ID has already been a new one Use the current ID to measure and store the data ID numbers are fully assigned If the number of the IDs has reached 60 delete some IDs Printed data texts are unreadable The baud rate may not be set properly Reset the printer s baud rate correctly Pressing the 開始 Start button does not start measuring Check the connection between the main body and ...

Page 28: ...ENTIONED ABOVE GIVEN BY ANY PERSON OR ENTITY WITH RESPECT TO THE PRODUCT SHALL BIND KJI KJI SHALL NOT BE LIABLE FOR LOSS OF STORAGE CHARGES LOSS OR CORRUPTION OF DATA OR ANY OTHER SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES CAUSED BY THE USE OR MISUSE OF OR INABILITY TO USE OR CONSEQUENTIAL DAMAGES CAUSED BY THE USE OR MISUSE OF OR INABILITY TO USE THE PRODUCT REGARDLESS OF THE LEGAL THEORY ON WHI...

Page 29: ...kanomax usa com JAPAN KANOMAX JAPAN INC 2 1 Shimizu Suita City Osaka 565 0805 Japan TEL 81 6 6877 0183 FAX 81 6 6879 5570 URL http www kanomax co jp E Mail sales kanomax co jp CHINA Shenyang Kano Scientific Instrument Co Ltd 2610 51 Wulihe Street Heping District Shenyang P R C TEL 86 24 23846440 FAX 86 24 23898417 URL http www kanomax com cn E Mail sales kanomax com cn 01001 15 06 ...

Page 30: ...30 ...