Kanomax 3080 User Manual Download Page 19

18 

 

Print Example 

 

Operating logs are printed by the Print. 

 
 
 
 
 
 
 

 

Measurement data are printed by the Print. 

 

(1) Repeat mode 

 
 
 
 
 

 
 
 

 

(2) Single mode 

 

 
 

 

2021 / 04 / 30        11: 00                                 

Number                  1 

User                        ADMIN 

        Operation              Delete file 

2021 / 04 / 30                                     

Number                   

Location                   

User                         

Volume                   

S-Time                 

F-Time           

Cycles                                         

Status                                           

11: 02 

ROOM001                 

ADMIN                                                                                                                                                                                                                                                         

200.0L 

00:02:10               

00:02:00                   

OK                   

2021 / 04 / 30                                     

Number                   

Location                   

User                         

Volume                   

S-Time                 

Cycles                                         

Status                                           

11: 05 

ROOM001                 

ADMIN                                                                                                                                                                                                                                                         

100.0L 

00:01:00                               

OK                   

Summary of Contents for 3080

Page 1: ...List of Components Microbial Air Sampler MODEL 3080 3081 User s Manual...

Page 2: ...ling AC Adapter 3081 10 Exclusive AC adapter USB Cable 3080 20 Connects between a PC the main unit and a printer RS485 Communication Terminal 3080 21 Communication connecting terminal between the PC a...

Page 3: ...ition that requires caution including warning The subject of each caution is illustrated inside the triangle e g the high temperature caution symbol is shown on the left This symbol indicates a prohib...

Page 4: ...Handling Handle the batteries properly in accordance with the following instructions Do not use the instrument and batteries in high temperature environments and or near heat sources This may cause ba...

Page 5: ...ded AC adaptor properly 1 Check that the voltage of the power supply outlet is within the range of the power supply voltage specifications 2 Use only grounded electrical outlets 3 When the product is...

Page 6: ...Petri Dish Power ON OFF 3 Measurement Procedure Power ON Measurement Power OFF Error 4 User Screen Log in Screen Main Screen General Setting Measurement Setting User History Print Example Remote Cont...

Page 7: ...Power switch Turns the power ON OFF 4 Handle For carrying the unit 5 USB port for PC Connects to the PC with the USB cable 6 USB port for Printer or USB memory Connects to a printer with the USB cabl...

Page 8: ...e and disinfect them in a high pressure sterilizer Wipe the surface of the instrument with sterile paper dampened with disinfectants Wipe the petri dish with sterile paper dampened with disinfectants...

Page 9: ...rt button to start measurement A measurement usually ends automatically To end a measurement during a measurement tap the measurement stop button To check measurement results use the history menu Powe...

Page 10: ...4 User Screen Log in Screen Input your user name and password and tap the Login button to show the main screen...

Page 11: ...Main Screen There are 2 main screens on the measurement mode Repeat Mode Single Mode...

Page 12: ...easurement Measurement Parameter Real time measurement time Remaining time until the end of a measurement is displayed Real time measurement volume Total measured volume is displayed in a real time ma...

Page 13: ...elds 20 year month day time minute second Data Checking stored data Remaining Displays the free space to the whole memory capacity Number of records Displays the number of data stored currently Copy a...

Page 14: ...rizations Reset password Modify calendar Copy files Delete files Change mode View logs Tap and save the settings with mark Information Displays the instrument information Last calibration The last cal...

Page 15: ...de in the previous measurement Repeat Repeats measurements the set number of measurement in accordance with a set delay time Single Performs a measurement once in accordance with a set delay time Sett...

Page 16: ...2 to 300 RS485 Performs measurements by operating through the PC Setting The connection method is RS485 Set communication parameters ID is the identification number of the instrument Connection Conne...

Page 17: ...s 64 in all Their input data can be changed as needed Step 1 Step 2 Step 3 Step 4 Select the User button Select a user on the list Enter the password for a user to be changed The default is 123456 Ent...

Page 18: ...tep 3 Step 4 Select the History button Select a measurement mode Display the operation log or measurement mode Perform data checking or printing Displays the history of the previous number Displays th...

Page 19: ...at mode 2 Single mode 2021 04 30 11 00 Number 1 User ADMIN Operation Delete file 2021 04 30 Number Location User Volume S Time F Time Cycles Status 11 02 1 ROOM001 ADMIN 200 0L 00 02 10 00 02 00 2 OK...

Page 20: ...the setting ID tap the Measurement start button of a required ID No to start a measurement 3 During the measurement pause the measurement to tap the Pause button of the ID No 4 While the measurement i...

Page 21: ...ly performed from the Layer 2 and less The Main screen for ready to measure is displayed when the instrument is not in the measuring process The Main screen for measurement is displayed when performin...

Page 22: ...flow rate the number of holes 20 m s 300 pcs 0 6 mm Authorization Administrator General users Petri dish 90 to 100 mm 55 to 84 mm Exhaust filter ISO class 3 3080 Display Operation 4 3 inch Liquid crys...

Page 23: ...o high The device may be faulty The reading is too low There is the dustproof cap or something on the sampling head Take them out If the error is still ON the fan will be fault or reach the end of its...

Page 24: ...with disinfectants The Surface of the Instrument Ammonium salts disinfectants of 1 000 to 2 000 mg L can be used as a disinfectant The effective time is 15 to 30 minutes Ethanol solutions Volume ratio...

Page 25: ...T has its serial number or date altered or removed 3 Loss or damage to the PRODUCT due to abuse mishandling improper packaging by the owner alteration accident electrical current fluctuations failure...

Page 26: ...omax usa com E Mail info kanomax usa com JAPAN KANOMAX JAPAN INC 2 1 Shimizu Suita City Osaka 565 0805 Japan TEL 81 6 6877 0183 FAX 81 6 6879 5570 URL http www kanomax co jp E Mail sales kanomax co jp...

Page 27: ......

Reviews: