25-63-50
© Orolia S.A.S.
Abbreviated Component Maintenance Manual
S1825501-01 / S1825501-02
Page 12
AUG 12/2013
Repair
TASK 25-63-50-300-801A01
1.
Repair
A.
General
(1)
Not applicable
Assembly
TASK 25-63-50-400-801A01
1.
Assembly
A.
General
Necessary tools and equipment:
to locate the under mentioned parts.
B.
Memory assembly
NOTE:
Necessary parts to perform this task are included in "EEPROM replacement kit" (See
, para D, Memory replacement).
CAUTION: INSERT CAREFULLY THE LEADS OF THE MEMORY IN THE SOCKET CHECKING
THAT THE LEADS ARE CORRECTLY INTRODUCED AND NOT FOLD UP.
(1)
Check the position of the indexing slots before positioning the memory on its socket (
).
(2)
On the I402 board (70), insert the memory (80) onto its socket.
(3)
Fill the memory replacement label (120) with the date of memory replacement and stick it on the
identification label (60) as shown
Figure 10001 / 25-63-50-991-09 CS144 Interface module,
C.
CR12 assembly
NOTE:
Necessary parts to perform this task are included in "CR12 replacement kit" (See
, para E, Upgrade).
(1)
Check the position of the indexing slot before positioning CR12 (85) as shown
detail
A.
(2)
Solder CR12 (85) on I402 board.
(3)
Connect J3.
(4)
, blacken the box B on I402 label.
(5)
Carry-out the electrical test of PCB (
refer to TASK 25-63-50-700-801A01
, para B (1)) before
closing the CS144.
(6)
As indicated
detail B, blacken the box B on label EES01610 stuck on the upper
cover.
(7)
Carry out the LRU test (