25-63-50
© Orolia S.A.S.
Abbreviated Component Maintenance Manual
S1825501-01 / S1825501-02
Page 13
AUG 12/2013
Figure 7001 / 25-63-50-991-07
CR12 position and labelling
D.
Desiccant capsule reassembly
(1)
Insert the new desiccant capsule (100) into the foam wedge (110)
(2)
Install the foam wedge into the housing as shown
Figure 3001 / 25-63-50-991-05 Internal View
.
E.
Closing the electronic compartment
CAUTION: TIGHTENING TORQUE FOR EIGHT TORX SCREWS (50): 0.9 +0, -0.1 NEWTON X
METER.
BEFORE TIGHTENING A SCREW, TURN IT COUNTER-CLOCKWISE TO FIND THE
START OF THE HOUSING THREAD (AUDIBLE CLICK).
(1)
Install a new O-Ring (90) on the upper lid (40).
(2)
Install the upper lid (40) in the correct assembly direction and install the eight TORX screws (50)
(3)
Tighten the 8 TORX screws (50) in the sequence shown below.
Figure 7002 / 25-63-50-991-08
Cover screw tightening
6
4
1
7
8
2
3
5