1. REASON

 PACK ELT KANNAD 406 AF-COMPACT (P/N S1840501-02) including KANNAD 406 AF-COMPACT 
transmitter (P/N S1840501-01) is supplied with RC200 Remote Control Panel (P/N S1820513-11) included 
in KIT, REMOTE CONTROL PANEL, RC200-COMPACT (P/N S1820513-20).

Some customers may choose to install a RC100 Remote Control Panel Kit (P/N S1820513-03) instead of 
RC200 Remote Control Panel.

This Service Letter is to provide information regarding the way to install a RC100 Remote Control Panel 
connected to KANNAD 406 AF-COMPACT transmitter (P/N S1840501-01).

2. EFFECTIVITY

3. ASSEMBLY PROCEDURE

A. General

CAUTION:

 

IF THE ELT HAS TO BE CONNECTED TO AN RC100 RCP ALREADY IN PLACE, BE AWARE 

THAT THE CONNECTION OF AN RC100 RCP INSTALLED WITH A KANNAD 406 AF-
COMPACT IS DIFFERENT FROM AN RC100 RCP CONNECTED WITH ANOTHER TYPE OF 
KANNAD ELT (S182X502-XX OR S181X502-XX).
CONNECTION OF RC100 RCP WITH KANNAD ELT (S182X502-XX OR S181X502-XX) 
REQUIRES A 4-WIRE BUNDLE.
CONNECTION OF RC100 RCP WITH KANNAD 406 AF-COMPACT REQUIRES A 3-WIRE 
BUNDLE.

DO NOT USE THE PREVIOUS CONNECTION AND CONNECT IT ACCORDING TO 

Figure 2: 

Wiring Diagram of RC100 RCP with KANNAD 406 AF-COMPACT

.

B. RC100 RCP Assembly

Assemble the items included in RC100 Kit as show

Figure 1: Assembly of RC100 RCP

 and as described 

in Installation Manual DMA 180 supplied with the Kit.
Note: this drawing (S1820825) is supplied with RC100 Remote Control Panel Kit.

C. Connection of RC100 to ELT transmitter

Connect the RCP to the ELT transmitter according to 

Figure 2: Wiring Diagram of RC100 RCP with KANNAD 

406 AF-COMPACT

Note: this drawing (S1820420) is supplied with RC100 Remote Control Panel Kit.

(1) Connect Pin 1 of switch to Resistor R1.

(2) Connect the other side of Resistor R1 to A of DIN12 connector (supplied with PACK S1840501-02) and 

to Pin 3 of switch.

(3) Connect Pin 2 of switch to G of DIN12 connector (supplied with PACK S1840501-02) and to any leg of 

the led (bipolar led).

(4) Connect the other leg of the led to J of DIN12 connector (supplied with PACKS1840501-02).

PACK ELT KANNAD 406 AF-COMPACT S1840501-02