SERVICE LETTER
KAN
NAD
Emergency Locator Transmitter
Page: 1 of 4
Date: JUL 07/2008
REV.: 01
© KANNAD 2008
SL_S1840501-25-01
PACK ELT KANNAD 406 AF-COMPACT
Compatibility of Kit, Remote Control Panel RC100
1. REASON
PACK ELT KANNAD 406 AF-COMPACT (P/N S1840501-02) including KANNAD 406 AF-COMPACT
transmitter (P/N S1840501-01) is supplied with RC200 Remote Control Panel (P/N S1820513-11) included
in KIT, REMOTE CONTROL PANEL, RC200-COMPACT (P/N S1820513-20).
Some customers may choose to install a RC100 Remote Control Panel Kit (P/N S1820513-03) instead of
RC200 Remote Control Panel.
This Service Letter is to provide information regarding the way to install a RC100 Remote Control Panel
connected to KANNAD 406 AF-COMPACT transmitter (P/N S1840501-01).
2. EFFECTIVITY
3. ASSEMBLY PROCEDURE
A. General
CAUTION:
IF THE ELT HAS TO BE CONNECTED TO AN RC100 RCP ALREADY IN PLACE, BE AWARE
THAT THE CONNECTION OF AN RC100 RCP INSTALLED WITH A KANNAD 406 AF-
COMPACT IS DIFFERENT FROM AN RC100 RCP CONNECTED WITH ANOTHER TYPE OF
KANNAD ELT (S182X502-XX OR S181X502-XX).
CONNECTION OF RC100 RCP WITH KANNAD ELT (S182X502-XX OR S181X502-XX)
REQUIRES A 4-WIRE BUNDLE.
CONNECTION OF RC100 RCP WITH KANNAD 406 AF-COMPACT REQUIRES A 3-WIRE
BUNDLE.
DO NOT USE THE PREVIOUS CONNECTION AND CONNECT IT ACCORDING TO
Wiring Diagram of RC100 RCP with KANNAD 406 AF-COMPACT
.
B. RC100 RCP Assembly
Assemble the items included in RC100 Kit as shown
Figure 1: Assembly of RC100 RCP
and as described
in Installation Manual DMA 180 supplied with the Kit.
Note: this drawing (S1820825) is supplied with RC100 Remote Control Panel Kit.
C. Connection of RC100 to ELT transmitter
Connect the RCP to the ELT transmitter according to
Figure 2: Wiring Diagram of RC100 RCP with KANNAD
Note: this drawing (S1820420) is supplied with RC100 Remote Control Panel Kit.
(1) Connect Pin 1 of switch to Resistor R1.
(2) Connect the other side of Resistor R1 to A of DIN12 connector (supplied with PACK S1840501-02) and
to Pin 3 of switch.
(3) Connect Pin 2 of switch to G of DIN12 connector (supplied with PACK S1840501-02) and to any leg of
the led (bipolar led).
(4) Connect the other leg of the led to J of DIN12 connector (supplied with PACKS1840501-02).
PACK ELT KANNAD 406 AF-COMPACT S1840501-02
Emergency Locator Transmitter
Remote Control Kit, RC100
S1820513-03
Remote Control Panel