- 24 -
7.
STORING AND RETRIEVING DATA
The KANE940 can store up to 100 combustion tests. Once stored, the data can be viewed on
the display or downloaded to a PC or printer.
7.1 Storing a ‘Live’ Test
While performing a test and viewing the data on the MAIN display access the STORE menu
as follows :-
Press STORE
MENU
to access the STORE MENU
MODE
LOCATION
:
S
TORE
:
3
PRESS ‘STORE’ TO LOG
Mode:
Select from the following :-
•
STORE
- Allows data to be stored in memory.
•
VIEW / PRINT
- Stored data can be viewed or printed.
•
DELETE
- Clears all data in memory.
Location:
Automatically allocates a location in the memory of the instrument for the next
test. On the display shown above the next location will be 3.
To store a test set
MODE
to
STORE
and press . The current readings will be stored in
the analysers memory.
Tip :
Make a note of the location number for your particular test as it may be useful
when downloading or printing.
7.2 Viewing and Printing a ‘Stored’ Test
Multiple tests can be printed easily with the KANE940.
Select PRINT under MODE in the STORE menu. This feature is in addition to the
VIEW/PRINT, STORE and DELETE options.
Press STORE
MENU
to access the STORE MENU
MODE
LOCATION
:
P
RINT
:
1 TO
10
PRESS ‘PRINT’
The cursor will move to the first number, use the and to select the location and
start printing.
Press to move the cursor to the second number, select the last location to print.